In this study, we investigated and compared the effect of different types of dissector (Maryland vs Hook) on changes in liver function tests (LFTs) after laparoscopic cholecystectomy.
The enrolled patients were divided into two groups. Group A patients underwent dissection by Maryland dissecting forceps, group B by Hook dissecting instrument. LFTs were measured preoperatively and at 1 day and 1 week, postoperatively.
Laparoscopic cholecystectomy (LC) is an alternative to laparotomy and has become the standard treatment of benign gallbladder diseases. However, it has been noted that (following LC) the serum level of certain liver function tests (LFT) raises markedly in patients who had preoperatively normal LFT. Pneumoperitoneum is the main contributing factor. This is the first study to evaluate the effect of different dissectors on alteration of LFTs after LC. As there were no statistical differences in the variation of LFTs between the Maryland and Hook, it seems that the dissector type has no effect on the alteration of LFTs.