      Inline UV/Vis spectroscopy as PAT tool for hot-melt extrusion.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Hot-melt extrusion on co-rotating twin screw extruders is a focused technology for the production of pharmaceuticals in the context of Quality by Design. Since it is a continuous process, the potential for minimizing product quality fluctuation is enhanced. A typical application of hot-melt extrusion is the production of solid dispersions, where an active pharmaceutical ingredient (API) is distributed within a polymer matrix carrier. For this dosage form, the product quality is related amongst others to the drug content. This can be monitored on- or inline as critical quality attribute by a process analytical technology (PAT) in order to meet the specific requirements of Quality by Design. In this study, an inline UV/Vis spectrometer from ColVisTec was implemented in an early development twin screw extruder and the performance tested in accordance to the ICH Q2 guideline. Therefore, two API (carbamazepine and theophylline) and one polymer matrix (copovidone) were considered with the main focus on the quantification of the drug load. The obtained results revealed the suitability of the implemented PAT tool to quantify the drug load in a typical range for pharmaceutical applications. The effort for data evaluation was minimal due to univariate data analysis, and in combination with a measurement frequency of 1 Hz, the system is sufficient for real-time data acquisition.

          Related collections

          Author and article information

          Journal
          Drug Deliv Transl Res
          Drug delivery and translational research
          Springer Science and Business Media LLC
          2190-3948
          2190-393X
          December 2018
          : 8
          : 6
          Affiliations
          [1 ] Institute of Solids Process Engineering, TU Dortmund University, Emil-Figge-Straße 68, 44227, Dortmund, Germany.
          [2 ] ColVisTec AG, Max-Planck-Straße 3, 12489, Berlin-Adlershof, Germany.
          [3 ] Institute of Solids Process Engineering, TU Dortmund University, Emil-Figge-Straße 68, 44227, Dortmund, Germany. markus.thommes@tu-dortmund.de.
          Article
          10.1007/s13346-017-0465-5
          10.1007/s13346-017-0465-5
          29327264
          92d5f9a3-1611-4659-a658-2ce397ea8ad0
          History

          Inline measurement,Process analytical technology,Process monitoring,Quality by Design,Twin screw extrusion,UV/Vis spectroscopy

          Comments

          Comment on this article