22
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence.

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Diffusion tensor imaging (DTI) requires a set of diffusion weighted measurements in order to acquire enough information to characterize local structure. The MRI scanner automatically performs a shimming process by acquiring a field map before the start of a DTI scan. Changes in B0, which can occur throughout the DTI acquisition due to several factors (including heating of the iron shim coils or subject motion), cause significant signal distortions that result in warped diffusion tensor (DT) parameter estimates. In this work we introduce a novel technique to simultaneously measure, report and correct in real time subject motion and changes in B0 field homogeneity, both in and through the imaging plane. This is achieved using double volumetric navigators (DvNav), i.e. a pair of 3D EPI acquisitions, interleaved with the DTI pulse sequence. Changes in the B0 field are evaluated in terms of zero-order (frequency) and first-order (linear gradients) shim. The ability of the DvNav to accurately estimate the shim parameters was first validated in a water phantom. Two healthy subjects were scanned both in the presence and absence of motion using standard, motion corrected (single navigator, vNav), and DvNav DTI sequences. The difference in performance between the proposed 3D EPI field maps and the standard 3D gradient echo field maps of the MRI scanner was also evaluated in a phantom and two healthy subjects. The DvNav sequence was shown to accurately measure and correct changes in B0 following manual adjustments of the scanner's central frequency and the linear shim gradients. Compared to other methods, the DvNav produced DTI results that showed greater spatial overlap with anatomical references, particularly in scans with subject motion. This is largely due to the ability of the DvNav system to correct shim changes and subject motion between each volume acquisition, thus reducing shear distortion.

          Related collections

          Author and article information

          Journal
          Neuroimage
          NeuroImage
          Elsevier BV
          1095-9572
          1053-8119
          Feb 01 2016
          : 126
          Affiliations
          [1 ] MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa. Electronic address: alkk1973@gmail.com.
          [2 ] MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa; African Institute for Mathematical Sciences (AIMS), South Africa.
          [3 ] Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Brookline, MA, USA.
          [4 ] MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa.
          Article
          S1053-8119(15)01044-7 NIHMS743106
          10.1016/j.neuroimage.2015.11.022
          4733594
          26584865
          dba683e7-8efe-4142-93cf-a86966dc4338
          History

          B0 correction,Diffusion tensor imaging (DTI),Double volumetric navigators (DvNav),Navigated diffusion sequence (vNav),The first-order shim (linear gradients),Zero-order shim (frequency)

          Comments

          Comment on this article