      Accuracy of Intraocular Lens Calculation Formulas.

      1 , 2 , 3
      Ophthalmology
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To compare the accuracy of intraocular lens (IOL) calculation formulas (Barrett Universal II, Haigis, Hoffer Q, Holladay 1, Holladay 2, Olsen, and SRK/T) in the prediction of postoperative refraction using a single optical biometry device.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: found
          • Article: not found

          Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis.

          The precision of intraocular lens (IOL) calculation is essentially determined by the accuracy of the measurement of axial length. In addition to classical ultrasound biometry, partial coherence interferometry serves as a new optical method for axial length determination. A functional prototype from Carl Zeiss Jena implementing this principle was compared with immersion ultrasound biometry in our laboratory. In 108 patients attending the biometry laboratory for planning of cataract surgery, axial lengths were additionally measured optically. Whereas surgical decisions were based on ultrasound data, we used postoperative refraction measurements to calculate retrospectively what results would have been obtained if optical axial length data had been used for IOL calculation. For the translation of optical to geometrical lengths, five different conversion formulas were used, among them the relation which is built into the Zeiss IOL-Master. IOL calculation was carried out according to Haigis with and without optimization of constants. On the basis of ultrasound immersion data from our Grieshaber Biometric System (GBS), postoperative refraction after implantation of a Rayner IOL type 755 U was predicted correctly within +/- 1 D in 85.7% and within +/- 2 D in 99% of all cases. An analogous result was achieved with optical axial length data after suitable transformation of optical path lengths into geometrical distances. Partial coherence interferometry is a noncontact, user- and patient-friendly method for axial length determination and IOL planning with an accuracy comparable to that of high-precision immersion ultrasound.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Development of the SRK/T intraocular lens implant power calculation formula

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of 9 intraocular lens power calculation formulas.

              To evaluate the accuracy of 9 intraocular lens (IOL) calculation formulas using 2 optical biometers.
                Bookmark

                Author and article information

                Journal
                Ophthalmology
                Ophthalmology
                Elsevier BV
                1549-4713
                0161-6420
                February 2018
                : 125
                : 2
                Affiliations
                [1 ] The Permanent Medical Group, Redwood City Medical Center, Redwood City, California. Electronic address: Ronald.Melles@kp.org.
                [2 ] Department of Ophthalmology, Baylor College of Medicine, Houston, Texas.
                [3 ] The Permanent Medical Group, Redwood City Medical Center, Redwood City, California.
                Article
                S0161-6420(17)31428-8
                10.1016/j.ophtha.2017.08.027
                28951074
                e0d7ab5a-1a30-4677-937b-2d2b1c4191b7
                History

                Comments

                Comment on this article