167
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Use and abuse of HOMA modeling.

      Diabetes Care
      Homeostasis, Humans, Insulin, secretion, Insulin Resistance, Islets of Langerhans, physiology, Liver, Models, Biological, Reproducibility of Results

      Read this article at

      ScienceOpenPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Homeostatic model assessment (HOMA) is a method for assessing beta-cell function and insulin resistance (IR) from basal (fasting) glucose and insulin or C-peptide concentrations. It has been reported in >500 publications, 20 times more frequently for the estimation of IR than beta-cell function. This article summarizes the physiological basis of HOMA, a structural model of steady-state insulin and glucose domains, constructed from physiological dose responses of glucose uptake and insulin production. Hepatic and peripheral glucose efflux and uptake were modeled to be dependent on plasma glucose and insulin concentrations. Decreases in beta-cell function were modeled by changing the beta-cell response to plasma glucose concentrations. The original HOMA model was described in 1985 with a formula for approximate estimation. The computer model is available but has not been as widely used as the approximation formulae. HOMA has been validated against a variety of physiological methods. We review the use and reporting of HOMA in the literature and give guidance on its appropriate use (e.g., cohort and epidemiological studies) and inappropriate use (e.g., measuring beta-cell function in isolation). The HOMA model compares favorably with other models and has the advantage of requiring only a single plasma sample assayed for insulin and glucose. In conclusion, the HOMA model has become a widely used clinical and epidemiological tool and, when used appropriately, it can yield valuable data. However, as with all models, the primary input data need to be robust, and the data need to be interpreted carefully.

          Related collections

          Most cited references33

          • Record: found
          • Abstract: found
          • Article: not found

          Homeostasis model assessment closely mirrors the glucose clamp technique in the assessment of insulin sensitivity: studies in subjects with various degrees of glucose tolerance and insulin sensitivity

          To evaluate whether the homeostasis model assessment (HOMA) is a reliable surrogate measure of in vivo insulin sensitivity in humans.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity.

            The oral glucose tolerance test (OGTT) has often been used to evaluate apparent insulin release and insulin resistance in various clinical settings. However, because insulin sensitivity and insulin release are interdependent, to what extent they can be predicted from an OGTT is unclear. We studied insulin sensitivity using the euglycemic-hyperinsulinemic clamp and insulin release using the hyperglycemic clamp in 104 nondiabetic volunteers who had also undergone an OGTT. Demographic parameters (BMI, waist-to-hip ratio, age) and plasma glucose and insulin values from the OGTT were subjected to multiple linear regression to predict the metabolic clearance rate (MCR) of glucose, the insulin sensitivity index (ISI), and first-phase (1st PH) and second-phase (2nd PH) insulin release as measured with the respective clamps. The equations predicting MCR and ISI contained BMI, insulin (120 min), and glucose (90 min) and were highly correlated with the measured MCR (r = 0.80, P < 0.00005) and ISI (r = 0.79, P < 0.00005). The equations predicting 1st PH and 2nd PH contained insulin (0 and 30 min) and glucose (30 min) and were also highly correlated with the measured 1st PH (r = 0.78, P < 0.00005) and 2nd PH (r = 0.79, P < 0.00005). The parameters predicted by our equations correlated better with the measured parameters than homeostasis model assessment for secretion and resistance, the delta30-min insulin/delta30-min glucose ratio for secretion and insulin (120 min) for insulin resistance taken from the OGTT. We thus conclude that predicting insulin sensitivity and insulin release with reasonable accuracy from simple demographic parameters and values obtained during an OGTT is possible. The derived equations should be used in various clinical settings in which the use of clamps or the minimal model would be impractical.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              U.K. Prospective Diabetes Study 16: Overview of 6 Years' Therapy of Type II Diabetes: A Progressive Disease

              (1995)
                Bookmark

                Author and article information

                Comments

                Comment on this article