      AN EVALUATION OF INDOOR ENVIRONMENTAL QUALITY AND OCCUPANT WELL-BEING IN MANITOBA SCHOOL BUILDINGS

      research-article

      Read this article at

      ScienceOpenPublisher
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This exploratory research aims to evaluate indoor environmental quality in the classrooms of three school buildings in Southern Manitoba, Canada, and to evaluate the well-being of these schools' teachers as it pertains to their perception of their classrooms' indoor environment. The schools include a middle-aged, conventional school; a new, non-green school; and a new, green school certified using the Leadership in Energy and Environmental Design rating system. The methodology involved using a mobile instrument cart to conduct snapshot measurements of thermal comfort, indoor air quality, lighting and acoustics in classrooms and an occupant survey to evaluate teachers' long-term satisfaction with their classrooms' indoor environmental quality. The results showed that the new, green and new, non-green schools' classrooms performed better than the conventional, middle-aged school's classrooms with respect to some aspects of thermal comfort and indoor air quality only. Teachers in the new, green school and in the new, non-green school were more satisfied than teachers in the conventional, middle-aged school with their classrooms' overall indoor environmental quality, lighting quality and indoor air quality. Surprisingly, the new, green and new-non green school classrooms' performance were very comparable with the new, green school's classrooms performing statistically significantly better with respect to relative humidity. Similarly, none of the differences in teachers' satisfaction ratings between the new, green and new, non-green school were statistically significant.

          Related collections

          Most cited references30

          • Record: found
          • Abstract: found
          • Article: not found

          Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature.

          To assess whether school environments can adversely affect academic performance, we review scientific evidence relating indoor pollutants and thermal conditions, in schools or other indoor environments, to human performance or attendance. We critically review evidence for direct associations between these aspects of indoor environmental quality (IEQ) and performance or attendance. Secondarily, we summarize, without critique, evidence on indirect connections potentially linking IEQ to performance or attendance. Regarding direct associations, little strongly designed research was available. Persuasive evidence links higher indoor concentrations of NO(2) to reduced school attendance, and suggestive evidence links low ventilation rates to reduced performance. Regarding indirect associations, many studies link indoor dampness and microbiologic pollutants (primarily in homes) to asthma exacerbations and respiratory infections, which in turn have been related to reduced performance and attendance. Also, much evidence links poor IEQ (e.g. low ventilation rate, excess moisture, or formaldehyde) with adverse health effects in children and adults and documents dampness problems and inadequate ventilation as common in schools. Overall, evidence suggests that poor IEQ in schools is common and adversely influences the performance and attendance of students, primarily through health effects from indoor pollutants. Evidence is available to justify (i) immediate actions to assess and improve IEQ in schools and (ii) focused research to guide IEQ improvements in schools. There is more justification now for improving IEQ in schools to reduce health risks to students than to reduce performance or attendance risks. However, as IEQ-performance links are likely to operate largely through effects of IEQ on health, IEQ improvements that benefit the health of students are likely to have performance and attendance benefits as well. Immediate actions are warranted in schools to prevent dampness problems, inadequate ventilation, and excess indoor exposures to substances such as NO(2) and formaldehyde. Also, siting of new schools in areas with lower outdoor pollutant levels is preferable.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Different aspects of assessing indoor and outdoor thermal comfort

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              An assessment of indoor environmental quality in schools and its association with health and performance

                Bookmark

                Author and article information

                Journal
                jgrb
                Journal of Green Building
                College Publishing
                1552-6100
                1943-4618
                1943-4618
                Winter 2017
                : 12
                : 1
                : 123-141
                Author notes

                1. Faculty of Engineering, Department of Civil Engineering, University of Manitoba, Room E1-368A EITC, 15 Gillson Street, Winnipeg, MB R3T 5V6 Canada Email: radwana@ 123456cc.umanitoba.ca (Corresponding author).

                2. Assistant Professor Faculty of Engineering, Department of Civil Engineering, University of Manitoba Room E3-589 EITC, 15 Gillson Street, Winnipeg, MB R3T 5V6, Canada Tel.: (204) 474-8786, Fax: (204) 474-7513 Email: Mohamed.Issa@ 123456umanitoba.ca

                Article
                jgb.12.1.123
                10.3992/1552-6100.12.1.123
                b7fc89b7-a962-4798-8ce2-a7b5786f7965
                © 2017 College Publishing
                History
                Page count
                Pages: 19
                Categories
                RESEARCH ARTICLES

                Urban design & Planning,Civil engineering,Environmental management, Policy & Planning,Architecture,Environmental engineering
                indoor environment,building energy use,post occupancy evaluation,building performance evaluation

                Comments

                Comment on this article