17
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found

      EXPERIMENTAL ANALYSIS OF DIFFERENT INSULATED FAÇADE TECHNOLOGIES IN SUMMER CONDITION

      research-article

      Read this article at

      ScienceOpenPublisher
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          ABSTRACT

          At the present, the ventilated façade is one of the most widely used and most innovative systems characterized by different energy saving features, but due to its complexity, the real performances are difficult to predict by numerical analysis. This work shows the results of the monitoring campaign conducted on two Cross Laminated Timber (CLT) test boxes equipped with different thermal coat technologies to realize the performances comparisons. In particular, the investigation focus on the evaluation of surface temperatures of the different wall layers and the indoor air temperature for: i) a micro ventilated façade and ii) two different ETICS solutions. The monitoring campaign has been conducted during the summer season on walls with equivalent thermal transmittance (U-value) and different thermal capacity. In detail, the experimental work has been performed to estimate the Isotec ® wall micro ventilated façade performance in comparison with two traditional ETICS technology: the first one realized with EPS and the second one with high density rock wool insulation. The results show that due to the shading effect provided by the external layer, the temperature within the cavity of the ventilate façade is reduced by 8–10 °C, reducing the cooling loads through the wall by 30–40% with respect to ETICS with EPS. The shading and the ventilation effects balance the presence of thermal insulation with less heat capacity; consequently, it validates the good quality of Isotec ® as wall technology with performances comparable to ETICS solution with high density rock wool insulation.

          Related collections

          Author and article information

          Journal
          jgrb
          Journal of Green Building
          College Publishing
          1552-6100
          1943-4618
          1943-4618
          Fall 2019
          : 14
          : 4
          : 77-91
          Author notes

          1. DABC—Department of Architecture Built Environment and Construction Engineering, Politecnico di Milano, Piazza Leonardo da Vinci,32 Milano, 20133, Italy, graziano.salvalai@ 123456polimi.it

          Article
          jgb.14.4.77
          10.3992/1943-4618.14.4.77
          15a3ec98-a1e3-451e-9644-d60df660bd09
          History
          Page count
          Pages: 15
          Categories
          RESEARCH ARTICLES

          Urban design & Planning,Civil engineering,Environmental management, Policy & Planning,Architecture,Environmental engineering
          micro ventilate façade,insulation comparison,performance assessment,in situ monitoring campaign,ETICS

          Comments

          Comment on this article