      XDS.

      Acta Crystallographica Section D: Biological Crystallography
      Crystallography, X-Ray, methods, Image Processing, Computer-Assisted, Software Design

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The usage and control of recent modifications of the program package XDS for the processing of rotation images are described in the context of previous versions. New features include automatic determination of spot size and reflecting range and recognition and assignment of crystal symmetry. Moreover, the limitations of earlier package versions on the number of correction/scaling factors and the representation of pixel contents have been removed. Large program parts have been restructured for parallel processing so that the quality and completeness of collected data can be assessed soon after measurement.

          Related collections

          Most cited references8

          • Record: found
          • Abstract: not found
          • Article: not found

          Automatic processing of rotation diffraction data from crystals of initially unknown symmetry and cell constants

          W Kabsch (1993)
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Improved R-factors for diffraction data analysis in macromolecular crystallography.

            The quantity Rsym (also called Rmerge) is almost universally used for describing X-ray diffraction data quality. Here, we prove that Rsym is seriously flawed, because it has an implicit dependence on the redundance of the data. A corrected R-factor, Rmeas, is introduced as the equivalent robust indicator of data consistency. In addition, we introduce Rmrgd an R-factor that reflects the gain in accuracy upon averaging of equivalent reflections, as a useful indicator of the quality of reduced data. These new data quality indicators better reveal the benefits of highly redundant data and should stimulate improvements in data quality through increased merging of data from multiple crystals.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              On the treatment of negative intensity observations

                Bookmark