29
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Fast extraction of amphenicols residues from raw milk using novel fabric phase sorptive extraction followed by high-performance liquid chromatography-diode array detection.

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A simple, sensitive, reliable, and fast analytical method was developed for the simultaneous determination of amphenicols residues in raw milk by combining fabric phase sorptive extraction (FPSE) and high-performance liquid chromatography-diode array detection. FPSE, a new generation green sample preparation technique, efficiently incorporates the advanced and tunable material properties of sol-gel derived microextraction sorbents with the rich surface chemistry of a cellulose fabric substrate, resulting in a flexible, highly sensitive, and fast microextraction device capable of extracting target analytes directly from complicated sample matrices. Due to the strong chemical bonding between the sol-gel sorbent and substrate, the microextraction device demonstrates a very high chemical and solvent stability. Therefore, any organic solvent/solvent mixture can be used as the eluent/back-extraction solvent. Herein, a highly polar polymer coated FPSE media was created using short-chain poly(ethylene glycol) (PEG) and the applicability of this novel microextraction device to extract highly polar amphenicol antibiotics from raw milk was investigated. Due to the intense affinity of amphenicols towards the strongly polar sol-gel PEG-coated FPSE device, absolute recovery of the selected antibiotics residues were found to be 44% for thiamphenicol, 66.4% for florfenicol, and 81.4% for chloramphenicol. The developed method was validated in terms of sensitivity, linearity, accuracy, precision, and selectivity according to European Decision 657/2002/EC. Decision limit (CCα) values were 52.49 μg kg(-1) for thiamphenicol, 55.23 μg kg(-1) for florfenicol, and 53.8 μg kg(-1) for chloramphenicol, while the corresponding results for detection capability (CCβ) were 56.8 μg kg(-1), 58.99 μg kg(-1), and 55.9 μg kg(-1), respectively.

          Related collections

          Author and article information

          Journal
          Anal. Chim. Acta
          Analytica chimica acta
          Elsevier BV
          1873-4324
          0003-2670
          Jan 15 2015
          : 855
          Affiliations
          [1 ] Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, Greece. Electronic address: samanidu@chem.auth.gr.
          [2 ] Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.
          [3 ] International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA. Electronic address: akabir@fiu.edu.
          [4 ] International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA.
          Article
          S0003-2670(14)01398-1
          10.1016/j.aca.2014.11.036
          25542088
          1e71d76e-eb54-41cd-a802-a32119aacd0d
          History

          Amphenicols,Milk,Fabric phase sorptive extraction (FPSE),Sorptive extraction,Sample preparation

          Comments

          Comment on this article