63
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment

      Read this article at

      ScienceOpenPublisher
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          FD technology enables reconstructive repair of otherwise difficult-to-treat intracranial aneurysms. These stentlike devices may induce progressive aneurysm thrombosis without additional implants and may initiate complete reverse vessel remodeling. The associated vascular biologic processes are as yet only partially understood. From 12 different centers, 13 cases of delayed postprocedural aneurysm rupture were recorded and analyzed. Symptom, aneurysm location and morphology, and the time elapsed from treatment until rupture were analyzed. There were 10 internal carotid and 3 basilar artery aneurysms. Mean aneurysm diameter was 22 ± 6 mm. Eleven patients were symptomatic before treatment. A single FD was used for all saccular aneurysms, while fusiform lesions were treated by using multiple devices. A supplementary loose coiling of the aneurysm was performed in 1 patient only. Ten patients developed early aneurysm rupture after FD treatment (mean, 16 days; range, 2-48 days); in 3 patients, rupture occurred 3-5 months after treatment. In all cases, most of the aneurysm cavity was thrombosed before rupture. The biologic mechanisms predisposing to rupture under these conditions are reviewed and discussed FDs alone may modify hemodynamics in ways that induce extensive aneurysm thrombosis. Under specific conditions, however, instead of reverse remodeling and cicatrization, aggressive thrombus-associated autolysis of the aneurysm wall may result in delayed rupture.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: found
          • Article: not found

          Remodeling of saccular cerebral artery aneurysm wall is associated with rupture: histological analysis of 24 unruptured and 42 ruptured cases.

          The cellular mechanisms of degeneration and repair preceding rupture of the saccular cerebral artery aneurysm wall need to be elucidated for rational design of growth factor or drug-releasing endovascular devices. Patient records, preoperative vascular imaging studies, and the snap-frozen fundi resected after microsurgical clipping from 66 aneurysms were studied. Immunostainings for markers of smooth muscle cell (SMC) phenotype, proliferation, and inflammatory cell subtypes and TUNEL reaction were performed. Unruptured (24) and ruptured (42) aneurysms had similar dimensions (median diameter in unruptured 6 mm; median in ruptured 7 mm; P=0.308). We identified 4 basic types of aneurysm wall that associated with rupture: (1) endothelialized wall with linearly organized SMCs (17/66; 42% ruptured), (2) thickened wall with disorganized SMCs (20/66; 55% ruptured), (3) hypocellular wall with either myointimal hyperplasia or organizing luminal thrombosis (14/66; 64% ruptured), and (4) an extremely thin thrombosis-lined hypocellular wall (15/66; 100% ruptured). Apoptosis, de-endothelialization, luminal thrombosis, SMC proliferation, and T-cell and macrophage infiltration associated with rupture. Furthermore, macrophage infiltration associated with SMC proliferation, and both were increased in ruptured aneurysms resected <12 hours from rupture, suggesting that these were not just reactive changes. Before rupture, the wall of saccular cerebral artery aneurysm undergoes morphological changes associated with remodeling of the aneurysm wall. Some of these changes, like SMC proliferation and macrophage infiltration, likely reflect ongoing repair attempts that could be enhanced with pharmacological therapy.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

            The Pipeline embolization device (PED) (Chestnut Medical Technologies, Inc., Menlo Park, CA) is a new microcatheter-delivered endovascular construct designed to achieve the curative reconstruction of the parent arteries giving rise to wide-necked and fusiform intracranial aneurysms. We present our initial periprocedural experience with the PED and midterm follow-up results for a series of 53 patients. Patients harboring large and giant wide-necked, nonsaccular, and recurrent intracranial aneurysms were selected for treatment. All patients were pretreated with dual antiplatelet medications for at least 72 hours before surgery and continued taking both agents for at least 6 months after treatment. A control digital subtraction angiogram was typically performed at 3, 6, and 12 months. Fifty-three patients (age range, 11-77 years; average age, 55.2 years; 48 female) with 63 intracranial aneurysms were treated with the PED. Small (n = 33), large (n = 22), and giant (n = 8) wide-necked aneurysms were included. A total of 72 PEDs were used. Treatment was achieved with a single PED in 44 aneurysms, with 2 overlapping PEDs in 17 aneurysms, and with 3 overlapping PEDs in 2 aneurysms. The mean time between the treatment and last follow-up digital subtraction angiogram was 5.9 months (range, 1-22 months). Complete angiographic occlusion was achieved in 56%, 93%, and 95% of aneurysms at 3 (n = 42), 6 (n = 28), and 12 (n = 18) months, respectively. The only aneurysm that remained patent at the time of the 12-month follow-up examination had been treated previously with stent-supported coiling. The presence of a preexisting endoluminal stent may have limited the efficacy of the PED reconstruction in this aneurysm. No aneurysms demonstrated a deterioration of angiographic occlusion during the follow-up period (i.e., no recanalizations). No major complications (stroke or death) were encountered during the study period. Three patients (5%), all with giant aneurysms, experienced transient exacerbations of preexisting cranial neuropathies and headache after the PED treatment. All 3 were treated with corticosteroids, and these symptoms resolved within 1 month. Endovascular reconstruction with the PED represents a safe, durable, and curative treatment of selected wide-necked, large and giant cerebral aneurysms. The rate of complete occlusion at the time of the 12-month follow-up examination approached 100% in the present study. To date, no angiographic recurrences have been observed during serial angiographic follow-up.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device.

              Aneurysm treatment by intrasaccular packing has been associated with a relatively high rate of recurrence. The use of mesh tubes has recently gained traction as an alternative therapy. This article summarizes the midterm results of using an endoluminal sleeve, the PED, in the treatment of aneurysms. A total of 19 wide-neck aneurysms were treated in 18 patients: 10 by implantation of PEDs alone and 9 by a combination of PED and coils. Angiographic and clinical results were recorded immediately and at 6 months following treatment. Immediate angiographic occlusion was achieved in 4 and flow reduction, in another 15 aneurysms. Angiography at 6 months demonstrated complete occlusion in 17 and partial filling in 1 of 18 patients. There was no difference between coil-packed and unpacked aneurysms. Of 28 side branches covered by > or =1 device, the ophthalmic artery was absent immediately in 1 and at 6 months in another 2 cases. One patient experienced abrupt in-stent thrombosis resulting in a transient neurologic deficit, and 1 patient died due to rupture of a coexisting aneurysm. All giant aneurysms treated with PED alone were demonstrated by follow-up cross-sectional imaging to have involuted by 6 months. Treatment of large, wide-neck, or otherwise untreatable aneurysms with functional reconstruction of the parent artery may be achieved with relative safety using dedicated flow-modifying devices with or without adjunctive use of intrasaccular coil packing.
                Bookmark

                Author and article information

                Journal
                American Journal of Neuroradiology
                AJNR Am J Neuroradiol
                American Society of Neuroradiology (ASNR)
                0195-6108
                1936-959X
                January 13 2011
                January 2011
                January 2011
                November 11 2010
                : 32
                : 1
                : 20-25
                Article
                10.3174/ajnr.A2370
                ca8ac23b-89bf-4b9f-a1d5-cb8cf30a56b0
                © 2010
                History

                Comments

                Comment on this article