57
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Motion-corrected whole-heart PET-MR for the simultaneous visualisation of coronary artery integrity and myocardial viability: an initial clinical validation

      European Journal of Nuclear Medicine and Molecular Imaging
      Springer Nature America, Inc

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: not found
          • Article: not found

          Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Whole-heart coronary MR angiography with 2D self-navigated image reconstruction.

            Several self-navigation techniques have been proposed to improve respiratory motion compensation in coronary MR angiography. In this work, we implemented a 2D self-navigation method by using the startup profiles of a whole-heart balanced Steady-state free precession sequence, which are primarily used to catalyze the magnetization towards the steady-state. To create 2D self-navigation images (2DSN), we added phase encoding gradients to the startup profiles. With this approach we calculated foot-head and left-right motion and performed retrospective translational motion correction. The 2DSN images were reconstructed from 10 startup profiles acquired at the beginning of each shot. Nine healthy subjects were scanned, and the proposed method was compared to a 1D self-navigation (1DSN) method with foot-head correction only. Foot-head correction was also performed with the diaphragmatic 1D pencil beam navigator (1Dnav) using a tracking factor of 0.6. 2DSN shows improved motion correction compared to 1DSN and 1Dnav for all coronary arteries and all subjects for the investigated diaphragmatic gating window of 10 mm. The visualized vessel length of the right coronary artery could be significantly improved with a multiple targeted 2D self-navigation approach, compared to 2DSN method. Copyright © 2011 Wiley Periodicals, Inc.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Highly efficient respiratory motion compensated free-breathing coronary MRA using golden-step Cartesian acquisition.

              To develop an efficient 3D affine respiratory motion compensation framework for Cartesian whole-heart coronary magnetic resonance angiography (MRA).
                Bookmark

                Author and article information

                Journal
                10.1007/s00259-018-4047-7
                http://creativecommons.org/licenses/by/4.0

                Comments

                Comment on this article