19
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Molecular isothermal techniques for combating infectious diseases: towards low-cost point-of-care diagnostics.

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Nucleic acid amplification techniques such as PCR have facilitated rapid and accurate diagnosis in central laboratories over the past years. PCR-based amplifications require high-precision instruments to perform thermal cycling reactions. Such equipment is bulky, expensive and complex to operate. Progressive advances in isothermal amplification chemistries, microfluidics and detectors miniaturisation are paving the way for the introduction and use of compact 'sample in-results out' diagnostic devices. However, this paradigm shift towards decentralised testing poses diverse technological, economic and organizational challenges both in industrialized and developing countries. This review describes the landscape of molecular isothermal diagnostic techniques for infectious diseases, their characteristics, current state of development, and available products, with a focus on new directions towards point-of-care applications.

          Related collections

          Most cited references65

          • Record: found
          • Abstract: found
          • Article: not found

          Nucleic acid sequence-based amplification.

          J. Compton (1991)
          Nucleic acid sequence-based amplification (NASBA) is a primer-dependent technology that can be used for the continuous amplification of nucleic acids in a single mixture at one temperature.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Miniaturized isothermal nucleic acid amplification, a review.

            Micro-Total Analysis Systems (µTAS) for use in on-site rapid detection of DNA or RNA are increasingly being developed. Here, amplification of the target sequence is key to increasing sensitivity, enabling single-cell and few-copy nucleic acid detection. The several advantages to miniaturizing amplification reactions and coupling them with sample preparation and detection on the same chip are well known and include fewer manual steps, preventing contamination, and significantly reducing the volume of expensive reagents. To-date, the majority of miniaturized systems for nucleic acid analysis have used the polymerase chain reaction (PCR) for amplification and those systems are covered in previous reviews. This review provides a thorough overview of miniaturized analysis systems using alternatives to PCR, specifically isothermal amplification reactions. With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future. The main isothermal methods as miniaturized systems reviewed here include nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP), helicase-dependent amplification (HDA), rolling circle amplification (RCA), and strand displacement amplification (SDA). Also, important design criteria for the miniaturized devices are discussed. Finally, the potential of miniaturization of some new isothermal methods such as the exponential amplification reaction (EXPAR), isothermal and chimeric primer-initiated amplification of nucleic acids (ICANs), signal-mediated amplification of RNA technology (SMART) and others is presented.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Microfluidic lab-on-a-foil for nucleic acid analysis based on isothermal recombinase polymerase amplification (RPA).

              For the first time we demonstrate a self-sufficient lab-on-a-foil system for the fully automated analysis of nucleic acids which is based on the recently available isothermal recombinase polymerase amplification (RPA). The system consists of a novel, foil-based centrifugal microfluidic cartridge including prestored liquid and dry reagents, and a commercially available centrifugal analyzer for incubation at 37 degrees C and real-time fluorescence detection. The system was characterized with an assay for the detection of the antibiotic resistance gene mecA of Staphylococcus aureus. The limit of detection was <10 copies and time-to-result was <20 min. Microfluidic unit operations comprise storage and release of liquid reagents, reconstitution of lyophilized reagents, aliquoting the sample into < or = 30 independent reaction cavities, and mixing of reagents with the DNA samples. The foil-based cartridge was produced by blow-molding and sealed with a self-adhesive tape. The demonstrated system excels existing PCR based lab-on-a-chip platforms in terms of energy efficiency and time-to-result. Applications are suggested in the field of mobile point-of-care analysis, B-detection, or in combination with continuous monitoring systems.
                Bookmark

                Author and article information

                Journal
                Expert Rev. Mol. Diagn.
                Expert review of molecular diagnostics
                Informa UK Limited
                1744-8352
                1473-7159
                Sep 2014
                : 14
                : 7
                Affiliations
                [1 ] Department of Molecular Microbiology, Hospital Sant Joan de Déu, University of Barcelona, Barcelona 08950, Spain.
                Article
                10.1586/14737159.2014.940319
                25052202
                2695c4bd-c7c0-4895-9dd6-32be470f01c9
                History

                molecular test,ASSURED,diagnostic,isothermal amplification,point-of care

                Comments