          ABSTRACT

          The proper consideration of daylight in indoor environments refers to guaranteeing sufficient light levels while minimizing the risks of glare. Currently, The International Organization Standardization-ISO and the International Commission on Illumination-CIE establish that, for classrooms, the proper lighting level oscillates between 300–500 lx. Despite this, there is evidence of differences in the daylighting levels perceived as sufficient. The objective of this article is to identify and to explain the differences in perception of daylighting sufficiency to perform typical reading and writing activities in four cities in Colombia with latitudes that oscillate between 3°25’18”N to 6°15’7”N: Armenia, Cali, Medellin and Manizales. A methodology that included the application of surveys to university students in classrooms was outlined; at the same time workplane illuminance was measured in the workstations and vertical illuminance at the height of the eyes of people. The results showed differences between cities in the proportion of people who perceive certain daylighting level as sufficiently illuminated. A logistic regression model showed that those differences can be explained from the global solar radiation of each city.

          Related collections

          Most cited references72

          • Record: found
          • Abstract: not found
          • Article: not found

          Modeling daylight availability and irradiance components from direct and global irradiance

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Useful daylight illuminances: A replacement for daylight factors

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Impact of windows and daylight exposure on overall health and sleep quality of office workers: a case-control pilot study.

              This research examined the impact of daylight exposure on the health of office workers from the perspective of subjective well-being and sleep quality as well as actigraphy measures of light exposure, activity, and sleep-wake patterns.
                Bookmark

                Author and article information

                Journal
                Journal of Green Building
                College Publishing
                1943-4618
                1552-6100
                March 01 2022
                June 21 2022
                March 01 2022
                June 21 2022
                : 17
                : 2
                : 181-209
                Article
                10.3992/jgb.17.2.181
                8f61e8c4-8892-4542-8c74-23aa05a001e2
                © 2022
                History

                Comments

                Comment on this article