      A comparative assessment of the accuracy of electronic apex locator (Root ZX) in the presence of commonly used irrigating solutions.

      Journal of Clinical and Experimental Dentistry
      Medicina Oral S.L.

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This study aimed to evaluate the accuracy of Root ZX in determining working length in presence of normal saline, 0.2% chlorhexidine and 2.5% of sodium hypochlorite.

          Related collections

          Most cited references47

          • Record: found
          • Abstract: found
          • Article: not found

          Apical limit of root canal instrumentation and obturation, part 2. A histological study.

          The results of an in vivo histological study involving apical and periapical tissues following root canal therapy after different observation periods demonstrated the most favourable histological conditions when the instrumentation and obturation remained at or short of the apical constriction. This was the case in the presence of vital or necrotic pulps, also when bacteria had penetrated the foramen and were present in the periapical tissues. When the sealer and/or the gutta-percha was extruded into the periapical tissue, the lateral canals and the apical ramifications, there was always a severe inflammatory reaction including a foreign body reaction despite a clinical absence of pain.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Electronic apex locators.

            Prior to root canal treatment at least one undistorted radiograph is required to assess canal morphology. The apical extent of instrumentation and the final root filling have a role in treatment success, and are primarily determined radiographically. Electronic apex locators reduce the number of radiographs required and assist where radiographic methods create difficulty. They may also indicate cases where the apical foramen is some distance from the radiographic apex. Other roles include the detection of root canal perforation. A review of the literature focussed first on the subject of electronic apex location. A second review used the names of apex location devices. From the combined searches, 113 pertinent articles in English were found. This paper reviews the development, action, use and types of electronic apex locators.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              In vitro assessment of the antimicrobial action and the mechanical ability of chlorhexidine gel as an endodontic irrigant.

              The objective of this study was to assess the chlorhexidine gluconate gel as an endodontic irrigant. First the ability of chlorhexidine gel to disinfect root canals contaminated in vitro with Enterococcus faecalis was investigated. A scanning electron microscope was also used to evaluate its cleansing ability compared with endodontic irrigants commonly used, such as sodium hypochlorite and chlorhexidine gluconate liquid. The results indicated that the chlorhexidine gel produced a cleaner root canal surface and had an antimicrobial ability comparable with that obtained with the other solutions tested. It was concluded that chlorhexidine gluconate in gel form has potential for use as an endodontic irrigant.
                Bookmark

                Author and article information

                Journal
                24596634
                3935904
                10.4317/jced.51230

                Comments

                Comment on this article