      Innovative Free-range Resonant Electrical Energy Delivery system (FREE-D System) for a ventricular assist device using wireless power.

      ASAIO journal (American Society for Artificial Internal Organs : 1992)
      Ovid Technologies (Wolters Kluwer Health)

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Technological innovation of a smaller, single moving part has an advantage over earlier large pulsatile ventricular assist devices (VADs) prone to mechanical failure. Drivelines limit the potential for extended patient survival durations with newer pumps and act as source for infection, increased morbidity, rehospitalizations, and reduced quality of life. The Free-range Resonant Electrical Energy Delivery (FREE-D) wireless power system uses magnetically coupled resonators to efficiently transfer power. We demonstrate the efficiency over distance of this system. The experimental setup consists of an radiofrequency amplifier and control board which drives the transmit resonator coil, and a receiver unit consisting of a resonant coil attached to a radiofrequency rectifier and power management module. The power management module supplies power to the axial pump, which was set at 9,600 rpm. To achieve a seamless wireless delivery in any room size, we introduced a third relay coil. This relay coil can be installed throughout a room, whereas a single relay coil could be built into a jacket worn by the patient, which would always be within range of the receive coil implanted in the patient's body. The power was delivered over a meter distance without interruptions or fluctuations with coil, rectifier, and regulator efficiency more than 80% and overall system efficiency of 61%. The axial pump worked well throughout the 8 hours of continuous operation. Having same setup on the opposite side can double the distance. A tether-free operation of a VAD can be achieved by FREE-D system in room-size distances. It has the potential to make the VAD therapy more acceptable from the patient perspective.

          Related collections

          Most cited references11

          • Record: found
          • Abstract: found
          • Article: not found

          Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association.

          Despite improvements in cardiovascular implantable electronic device (CIED) design, application of timely infection control practices, and administration of antibiotic prophylaxis at the time of device placement, CIED infections continue to occur and can be life-threatening. This has prompted the study of all aspects of CIED infections. Recognizing the recent advances in our understanding of the epidemiology, risk factors, microbiology, management, and prevention of CIED infections, the American Heart Association commissioned this scientific statement to educate clinicians about CIED infections, provide explicit recommendations for the care of patients with suspected or established CIED infections, and highlight areas of needed research.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Analysis, Experimental Results, and Range Adaptation of Magnetically Coupled Resonators for Wireless Power Transfer

              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Efficient wireless non-radiative mid-range energy transfer

              , , (2006)
              We investigate whether, and to what extent, the physical phenomenon of long-lifetime resonant electromagnetic states with localized slowly-evanescent field patterns can be used to transfer energy efficiently over non-negligible distances, even in the presence of extraneous environmental objects. Via detailed theoretical and numerical analyses of typical real-world model-situations and realistic material parameters, we establish that such a non-radiative scheme could indeed be practical for medium-range wireless energy transfer.
                Bookmark

                Author and article information

                Journal
                24299972
                10.1097/MAT.0000000000000029

                Comments

                Comment on this article