324
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Computed tomography--an increasing source of radiation exposure.

      The New England journal of medicine

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references30

          • Record: found
          • Abstract: found
          • Article: not found

          Cancer risks attributable to low doses of ionizing radiation: assessing what we really know.

          High doses of ionizing radiation clearly produce deleterious consequences in humans, including, but not exclusively, cancer induction. At very low radiation doses the situation is much less clear, but the risks of low-dose radiation are of societal importance in relation to issues as varied as screening tests for cancer, the future of nuclear power, occupational radiation exposure, frequent-flyer risks, manned space exploration, and radiological terrorism. We review the difficulties involved in quantifying the risks of low-dose radiation and address two specific questions. First, what is the lowest dose of x- or gamma-radiation for which good evidence exists of increased cancer risks in humans? The epidemiological data suggest that it is approximately 10-50 mSv for an acute exposure and approximately 50-100 mSv for a protracted exposure. Second, what is the most appropriate way to extrapolate such cancer risk estimates to still lower doses? Given that it is supported by experimentally grounded, quantifiable, biophysical arguments, a linear extrapolation of cancer risks from intermediate to very low doses currently appears to be the most appropriate methodology. This linearity assumption is not necessarily the most conservative approach, and it is likely that it will result in an underestimate of some radiation-induced cancer risks and an overestimate of others.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries.

            Diagnostic X-rays are the largest man-made source of radiation exposure to the general population, contributing about 14% of the total annual exposure worldwide from all sources. Although diagnostic X-rays provide great benefits, that their use involves some small risk of developing cancer is generally accepted. Our aim was to estimate the extent of this risk on the basis of the annual number of diagnostic X-rays undertaken in the UK and in 14 other developed countries. We combined data on the frequency of diagnostic X-ray use, estimated radiation doses from X-rays to individual body organs, and risk models, based mainly on the Japanese atomic bomb survivors, with population-based cancer incidence rates and mortality rates for all causes of death, using life table methods. Our results indicate that in the UK about 0.6% of the cumulative risk of cancer to age 75 years could be attributable to diagnostic X-rays. This percentage is equivalent to about 700 cases of cancer per year. In 13 other developed countries, estimates of the attributable risk ranged from 0.6% to 1.8%, whereas in Japan, which had the highest estimated annual exposure frequency in the world, it was more than 3%. We provide detailed estimates of the cancer risk from diagnostic X-rays. The calculations involved a number of assumptions and so are inevitably subject to considerable uncertainty. The possibility that we have overestimated the risks cannot be ruled out, but that we have underestimated them substantially seems unlikely.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              CT dose reduction and dose management tools: overview of available options.

              In the past decade, the tremendous advances in computed tomography (CT) technology and applications have increased the clinical utilization of CT, creating concerns about individual and population doses of ionizing radiation. Scanner manufacturers have subsequently implemented several options to appropriately manage or reduce the radiation dose from CT. Modulation of the x-ray tube current during scanning is one effective method of managing the dose. However, the distinctions between the various tube current modulation products are not clear from the product names or descriptions. Depending on the scanner model, the tube current may be modulated according to patient attenuation or a sinusoidal-type function. The modulation may be fully preprogrammed, implemented in near-real time by using a feedback mechanism, or achieved with both preprogramming and a feedback loop. The dose modulation may occur angularly around the patient, along the long axis of the patient, or both. Finally, the system may allow use of one of several algorithms to automatically adjust the current to achieve the desired image quality. Modulation both angularly around the patient and along the z-axis is optimal, but the tube current must be appropriately adapted to patient size for diagnostic image quality to be achieved. (c) RSNA, 2006.
                Bookmark

                Author and article information

                Journal
                18046031
                10.1056/NEJMra072149

                Comments

                Comment on this article

                scite_

                Similar content529

                Cited by1,314