64
views
0
recommends
+1 Recommend
1 collections
    0
    shares

      Authors - did you know Parasite has been awarded the DOAJ Seal for “best practice in open access publishing”?

      • 3.020 2021 Impact Factor
      • Rapid publication and moderate publication fee
      • Creative Commons license
      • Long articles welcome – no page limits

      Instructions for authors, online submissions and free e-mail alerts all available at parasite-journal.org

      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Laparoscopic approach for total cystectomy in treating hepatic cystic echinococcosis

      Read this article at

      ScienceOpenPublisher
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background: The laparoscopic approach has been proposed for treating hepatic cystic echinococcosis (HCE) and has already been used in clinical practice, mostly for non-radical operations. In this study, we aimed to evaluate the feasibility of total cystectomy of HCE under laparoscopy (LS). Results: A retrospective review of the medical records obtained from 22 patients diagnosed with HCE between June 2009 and June 2013 and treated with an LS approach was conducted in the First Affiliated Hospital of Xinjiang Medical University. A total of 15 patients underwent total cystectomy of HCE using LS. The average time of surgery was 174 min (160–210 min). Intraoperative bleeding was 103 mL (80–200 mL). The mean duration of hospitalization was 7 days (6–15 days). Seven patients were transferred to open surgery (OS). For these patients, the average duration of surgery was 177 min (150–230 min). Intraoperative bleeding was 237 mL (160–350 mL), and the mean duration of hospitalization was 10 days (8–15 days). The most frequent postoperative complications were hydrops in the surgical area (two cases in LS and three cases in OS), and temporary bile leakage (one patient in the LS group). Recurrence was not seen in any cases in either group with a follow-up of 6–12 months. Conclusions: Total cystectomy of HCE appears to be safe and effective in selected patients with unique, small-sized, superficially located cysts. To establish precise recommendations about the technique and its indications, prospective studies are necessary.

          Related collections

          Most cited references10

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Diagnosing and Staging of Cystic Echinococcosis: How Do CT and MRI Perform in Comparison to Ultrasound?

          Introduction Cystic echinococcosis (CE) is a neglected parasitic disease of global distribution [1], [2]. The highest prevalence rates are recorded in South America, Northern and Eastern Africa, Eurasia and Australia. In non-endemic and largely high income countries CE is a disease of immigrants. Imaging plays the key role in diagnosing and staging of CE, whereas serology has only a minor, confirmatory role due to high rates of false negative results [3]. This is particularly the case in the early cyst stages when hydatid fluid is still tightly contained within the endocysts (cyst stage CE1) and in the final stage of involution (CE5) when cyst content is solid and the cyst wall largely calcified. The description of CE-specific imaging features and CE cyst classification is based on ultrasound (US). A set of ultrasonographic features has been agreed upon as the imaging reference standard for diagnosing and staging CE, resulting in a standardized WHO classification based on the Gharbi US classification of 1981 [4]–[7], [17] (Figure 4). Through ultrasound substantial progress has been made in recent years in understanding the natural and treatment driven involution of CE cysts . This to an extent that treatment decision can increasingly be based on cyst stages. By and large CE1, CE2 are regarded as “active”, CE3 as “transitional” and CE4 and CE5 as “inactive” cyst stages [6]–[9], [17]. In uncomplicated cysts, the four available treatment modalities can be assigned to these cyst stages: small early cysts, in particular CE1, can be given a trial with albendazole [10] and larger CE1 liver cysts up to a diameter of 10 cm are ideal for PAIR. For advanced cysts (CE4 and CE5) good evidence has accumulated that they can confidently be left alone (watch & wait). More critical are CE2 and the transitional cyst stage CE3b which often need surgery for definite cure. Identification of cysto-biliary and cysto-bronchial communications is critical, in particular when protoscolicidal substances are used to sterilize the endocyst and cyst content. Imaging, specifically magnetic resonance imaging (MRI) with heavily T2-weighted series [11], plays a role here, but can not completely rule out communications pre-interventionally. Computed tomography (CT) and MR imaging features of CE cysts have also been well characterized [12]–[14]. But there is a lack of systemic comparisons between different imaging modalities in CE. We systematically searched PubMed from its beginnings until July 29th, 2012 with the search terms [(cystic echinococcosis or hydatid disease) and (CT or MRI or MR)] and retrieved 1351 results. Only 2 publications compared at least two of the imaging modalities US, MRI and CT. Suwan [15] compared US (N = 62) with CT (N = 25) and Taourel et al [16] CT and MRI (N = 27). Suwan found that sonography was superior to CT in the characterization of cyst content but CT was superior to sonography in detecting gas within the cysts and minute calcifications. Taourel et al concluded that MRI was superior to CT in identifying complications but did not help to characterize solid or pseudotumoral forms of CE. The role of CT and MRI in staging CE has never been evaluated, however. This is of particular importance for cyst which are nor accessible by US and because of the increasing availability and overuse of CT and MR imaging to avoid misclassification. We present a data set of US-, MRI- and CT-investigations of patients with CE to determine the performance of CT and MRI in comparison to the gold standard US. Methods The Section of Clinical Tropical Medicine at Heidelberg University Hospital runs an interdisciplinary clinic for patients with CE since 1999. Clinical, serological and radiological data of patients attending the clinic are systematically registered and patients are followed-up for 5–10 years after completion of treatment. All images are stored in a Picture Archiving and Communication System (PACS; Centricity, Version 2.0, GE Medical Systems Integrated Imaging Solutions, Mt. Prospect, USA) since February 2000. Over the years diagnosis and treatment of patients has been highly standardized. Patients are triaged into four treatment groups: albendazole, PAIR (puncture, aspiration, injection of a scolecidal agent and reaspiration), surgery and watch & wait as previously reviewed [7], [8], [17]. Patients The patients with abdominal or soft tissue echinococcal cysts who had CT and/or MRI scans performed additionally to US imaging within a time period of three months were selected from our Picture Archiving and Communication System. Albendazole treatment before and during the 3-months period of assessment was not taken into account. In total 107 patients with 187 abdominal cysts were included into our study. The Institutional Review Board of the University Hospital of Heidelberg has approved this retrospective analysis of clinical data and radiological examinations (reference number: 243/2011). Ultrasound examination (US) All cysts (n = 187) were examined by US with conventional B mode US using a Sonoline Elegra platform (Siemens Ultrasound Division, Issaquah, Washington, USA) or a Logiq 9 platform (GE, Milwaukee, USA) with a 3.5 MHz and 7 MHz multifrequency transducer. Computed tomography (CT) A total number of 138 cysts were examined by unenhanced and contrast-enhanced CT, of which 112 cysts were recorded on CTs from external radiological institutions. 26 cysts were examined in-house using different scanner generations with 4, 16, 64, and 256 slice technology (Siemens Somatom, Sensation, Definition, Forchheim, Germany; Philips Brilliance 64 and iCT, Philips Healthcare, The Netherlands). CTs of all patients were run with a routine abdominal protocol with unenhanced and contrast enhanced scans. Images were reconstructed with a slice thickness between 3 and 5 mm and overlapping reconstruction increment. Magnetic resonance imaging (MRI) In total, 125 cysts were examined by MRI of which 45 cysts were digitally recorded from external radiological institutions. 80 cysts were examined in-house using 1.5 Tesla systems Magnetom Symphony equipped with a high-performance gradient system (maximum gradient strength: 30 mT/m, slew rate: 125 T/m/s) and since May 2004 on a Siemens Avanto Symphony equipped with a 40 mT/m gradient system and a slew rate of 170 T/(m/s). The in-house MRI protocol with detailed sequence parameters is listed in Table 1. 10.1371/journal.pntd.0001880.t001 Table 1 In-house MRI protocols with detailed sequence parameters. Symphony Avanto TrueFisp 1 TR2/TE3 [ms] 4.3/2.15 5.18/2.59 flip angle [°] 51 80 slice thickness [mm] 6 6 matrix size 256×256 384×512 T1w FLASH 4 TR/TE [ms] 128/4.76 168/4.76 flip angle [°] 70 70 slice thickness [mm] 6 6 matrix size 256×267 256×256 T2w TSE 5 TR/TE [ms] 3220/109 4050/112 flip angle [°] 150 150 slice thickness [mm] 6 6 matrix size 256×256 256×256 HASTE 6 TR/TE [ms] 1400/105 1530/119 flip angle [°] 125 160 slice thickness [mm] 6 6 matrix size 256×512 256×512 post-contrast T1w 3D-FLASH TR/TE [ms] 3.73/1.44 3.5/1.31 flip angle [°] 25 12 slice thickness [mm] 2.5 3 matrix size 343×512 384×512 T1w 2D-FLASH TR/TE [ms] 157/6 142/6 flip angle [°] 70 70 slice thickness [mm] 8 8 matrix size 256×256 256×256 1 TrueFisp: True Fast Imaging With Steady Precession, 2 TR: Repetition Time, 3 TE: Time to Echo. 4 FLASH: Fast Low Angle Shot, 5 TSE: Turbo-Spin-Echo, 6 HASTE: Half fourier-Acquired Single shot Turbo spin Echo, w: weighted. Evaluation of US, MRI and CT images All images were interpreted by the same Board-examined senior staff radiologist (WH) experienced in the diagnosis of CE and member of WHO Informal Working Group on Echinococcosis (WHO-IWGE). US, CT and MR images were assessed using a Picture Archiving and Communication System (PACS; Centricity, Version 2.0, GE Medical Systems Integrated Imaging Solutions, Mt. Prospect, USA). CT and MR images of external radiological institutions have been imported into the PACS system. The CT, MRI and US series were separately read in random order. In the final step, the results of the three imaging modalities were matched to the patient. The optimal window setting for analyzing the images of each case in the PACS was adjusted individually as needed. To evaluate which standard MRI sequence is best for the classification of echinococcal cysts abdominal T2w-standard sequences TrueFisp (True Fast Imaging With Steady Precession), HASTE (Half fourier-Acquired Single shot Turbo spin Echo), T2w-TSE (T2-weighted Turbo-Spin-Echo), as well as contrast enhanced T1w FLASH (Fast Low Angle Shot) or the corresponding sequences of other manufacturers than Siemens (n = 13) were evaluated in a separate session. Independent of the imaging modality cysts were staged according to WHO classification [4], [17], [18] (Figure 4). The following thresholds for CT assessment were used: 0 to 20 Hounsfield Units (HU) to identify liquid cyst content, 20 to 130 HU for mucinous or solid content, and 130 HU or higher on unenhanced images to identify calcification. For MRI assessment liquid cyst content has been identified on T2w sequences by comparing its signal intensity with liquid content of the gallbladder or CSF in the spinal canal for reference. Statistical analysis We analysed agreement between the cyst stages as determined by CT or MRI and US which was defined as the standard of reference. The agreement beyond chance was quantified by kappa coefficients. Kappa values from 0.81–1.0 were considered very good, values from 0.61–0.80 good and 0.41–0.60 as moderate [19]. Confidence intervals for the kappa coefficients were calculated using the Stata command “kapci”. As described by Reichenheim [23], the calculation is based on an analytical method in the case of dichotomous variables [20] and a bias corrected bootstrap method in the case of nominal variables [21], [22] (see Stata documentation on the command “kapci”). The number of bootstrap replications was set to 1000. A chi-square test for heterogeneity between kappa coefficients of in-domo and ex-domo MRI scans was performed in a meta-analytic framework using the Stata command “metan” [24]. The kappa coefficients and the corresponding confidence intervals estimated as indicated above were used as input for the meta-analysis. All calculations were done in Stata versions 9.2 and 12.1 (STATA Corporation, College Station, Texas). Results 107 patients with 187 CE cysts met the inclusion criteria. 47 patients were female, 60 male. The age of the patients ranged from 7–78 years. The cyst localisation was: 171 liver, 6 spleen, 3 kidney, 5 peritoneum, 2 in the soft tissue. Median maximal cyst diameter was 5.5 cm ranging from 1 to 23 cm. All 187 cysts were assessed by US, 138 by CT, and 125 by MRI. Figure 1 shows the distribution of WHO cyst stages as determined by US. 10.1371/journal.pntd.0001880.g001 Figure 1 Number of cysts per WHO cyst stage (CE 1–5) as determined by US (N = 187). Figure 2 shows a scatter plot of the WHO classification-based cyst staging with a level of agreement beyond chance of the individual CE stages 1–4 clearly lower for CT, with κ ranging from 0.62 to 0.72, compared to MRI with values of κ between 0.83 and 1.0. For CE5 cysts CT (κ = 0.95) performed better than MRI (κ = 0.65) (Table 2, 3). 10.1371/journal.pntd.0001880.g002 Figure 2 Scatter plots of the agreement beyond chance of US vs. CT and US vs. MRI. 10.1371/journal.pntd.0001880.t002 Table 2 Levels of agreement and kappa coefficients for US vs. CT, US vs. MRI and US vs. different MRI sequences. Method N° of cysts Agreement (%) Expected Agreement (%) Kappa Std. Err. 95% CI CT 138 76.09 18.40 0.71 0.0391 (0.61–0.79) MRI 125 92.00 22.97 0.90 0.0460 (0.83–0.95) T1w-FLASH 1 125 72.80 22.98 0.65 0.0455 (0.55–0.74) T2w-TSE 2 118 81.36 21.90 0.76 0.0461 (0.68–0.85) TrueFisp 3 100 86.00 24.57 0.81 0.0528 (0.72–0.90) HASTE 4 120 91.67 23.06 0.89 0.0471 (0.83–0.95) 1 FLASH: Fast Low Angle Shot, 2 TSE: Turbo-Spin-Echo, 3 TrueFisp: True Fast Imaging With Steady Precession, 4 HASTE: Half fourier-Acquired Single shot Turbo spin Echo (or corresponding sequences of other manufacturers than Siemens). Differences in number of cysts are due to varieties in MRI-protocols, especially of ex-domo-patients. 10.1371/journal.pntd.0001880.t003 Table 3 Levels of agreement and kappa coefficients for US vs. CT and for US vs. MRI stratified by WHO stages (defined by US). US versus CT (N = 138) Cyst stage Agreement (%) Expected Agreement (%) Kappa Std. Err. 95% CI 1 92.75 80.36 0.63 0.0791 (0.43–0.84) 2 92.75 77.27 0.68 0.0844 (0.50–0.87) 3a 92.03 78.73 0.63 0.0810 (0.43–0.82) 3b 91.30 68.52 0.72 0.0850 (0.58–0.87) 4 84.78 59.70 0.62 0.0848 (0.48–0.77) 5 98.55 72.21 0.95 0.0850 (0.88–1.00) US versus MRI (overall) (N = 125) Cyst stage Agreement (%) Expected Agreement (%) Kappa Std. Err. 95% CI 1 99.20 83.29 0.95 0.0893 (0.86–1.00) 2 99.20 79.49 0.96 0.0894 (0.89–1.00) 3a 100.00 77.68 1.00 0.0894 (1.00–1.00) 3b 96.00 57.29 0.91 0.0890 (0.83–0.99) 4 92.80 57.34 0.83 0.0893 (0.73–0.94) 5 96.80 90.85 0.65 0.0881 (0.33–0.97) Cyst-stage specific kappa values: CT are more to the lower end of the category “good” (0.61–0.80), MRI at the upper end of the category “very good” (0.81–1.0). Comparison between US and individual MRI sequences for MRI examinations are shown in Figure 3. The highest level of agreement was found between US and HASTE with a kappa coefficient of 0.89 and US and TrueFisp with a kappa coefficient of 0.81. See Table 2 for details. The results of in-domo MRI scans run with standardized protocols and ex-domo MRI scans with varying protocols and sequence parameters have been pooled, because no significant differences were found in the level of agreement beyond chance between MRI and US (Chi2-Test for heterogeneity between kappa values of in-domo and ex-domo MRI: p = 0.395; data not shown). Differences between in-domo and ex-domo in CT examinations do not need to be considered, because of comparable imaging and reconstruction protocols. 10.1371/journal.pntd.0001880.g003 Figure 3 Scatter plots of the agreement beyond chance of US versus MRI. Scatter plots of the agreement beyond chance of US versus contrast enhanced T1w-FLASH, TrueFisp, HASTE and T2w-TSE MRI modes. Discussion Imaging plays the key role in diagnosing and staging CE cysts. The description of CE-specific imaging features and the WHO-IWGE CE cyst classification is based on ultrasound. The reproducibility of the ultrasound-defined features of CE cysts is variable in MR- and CT-imaging. Since treatment decisions are driven by imaging it is important to know how the ultrasound-based classification of CE cysts translates into MR- and CT-imaging for cases where MRI and CT substitute for US. This is in cysts which are not accessible for US, but plays also an increasing role due to widespread availability and overuse of CT and MR imaging. Compared to the reference standard ultrasound, the performance of MRI may be a problem in WHO cyst stages CE4 and 5, and is definitely a problem in CT imaging in a much wider range of cysts (CE1, CE2, CE 3a, b, CE4). Figure 4 and 5 show typical US, MR- and CT-images with the “best case“ for CT/MR imaging and the “worst case” for CT/MR imaging, whereby the “best case” of cyst stages CE2, CE3a,b and CE4 is rarely achieved by CT scanning. 10.1371/journal.pntd.0001880.g004 Figure 4 “Best case” of CT/MR imaging. CE1: unilocular, simple cysts with liquid content and often with the CE1-specific “double line sign”, CE2: multivesicular, multiseptated cysts, CE3a: cysts with liquid content and the CE3a-specific detached endocyst, CE3b: unilocular cysts with daughter cysts inside a mucinous or solid cyst matrix, CE4: heterogenous solid cysts with degenerative, CE4-specific canalicular structure of the cyst content, and CE5: cysts with degenerative content and heavily calcified wall. 10.1371/journal.pntd.0001880.g005 Figure 5 “Worst case” of CT/MR imaging. The “double line sign”, typical for CE1 is often seen in US (CE1/US, arrow), less reliably in MRI and CT. Daughter cysts and detached endocyst (“water-lily-sign”) is often missed by CTs, but clearly visible in US and MRI (see CE2, CE3a, arrows). Daughter cysts inside a solid cyst matrix are often not recognized by CT (CE3b, arrows). The CE4-specific canalicular structure is often not visible on CT images. These cysts may be misinterpreted as type CE1 cysts, i.e. staged “active” instead of “inactive”. The identification of calcifications is the domain of CT imaging. MRI does not differentiate well between thick hyaline walls and calcifications. US picks up calcifications only when a dorsal echo shadow is produced (see CE5, arrows). MRI: HASTE sequence, CT: post contrast enhanced images. Our data shows that cyst stages CE1 to CE4 determined by MRI compared to the reference standard US have a very good level of agreement with a kappa value between 0.83–1.00. Analysis of individual MRI sequences exhibit similar accordance. In HASTE sequences the kappa value is 0.89. T2-weighted sequences, in particular TrueFisp and HASTE sequences, detect liquid content in the cyst matrix best, i.e. daughter cysts (CE2, CE3b) and septae (CE2). In contrast cysts staged CE1 to CE4 evaluated by CT show clearly lower kappa values which range between 0.62 and 0.72. Compared to ultrasound CT performs satisfactorily in CE5 cysts (κ = 0.95). This is due to the amount of calcifications for what CT is the diagnostic standard. In all other cysts in which the texture of the cyst matrix is of importance for classification CT performs moderately. MRI has shortcomings in identifying details of the cyst wall, in particular calcifications which play some role in defining cyst stage CE5 with a kappa of 0.65. Cyst wall calcification is, however, not a cyst stage defining feature in itself as has been recently shown in a large data set [11]. The highly specific cyst stage defining features are features of the cyst matrix with the exception of the “double line sign” of CE1 (see Figure 4, 5) where a cyst wall feature is diagnostic. MRI and in particular heavily T2w sequences (e.g. HASTE sequences) show a performance which is comparable to US. The superiority of MRI in comparison to CT imaging in staging CE cysts is in line with the well known observation in both the detection and characterization of focal liver lesions in general despite the fact that CT imaging provides very high spatial as well as temporal resolution, due to its superior soft tissue contrast [25], [26]. A possible limitation of our study is that there was some variation in CT and MR imaging protocols between patients due to the retrospective study design. However, when comparing the two main subpopulations, the in-house MRI scans run with standardized protocols and the ex-domo MRI scans with varying protocols and sequence parameters, no significant differences were found in the level of agreement beyond chance between MRI and US. Another limitation is that only one radiologist read the images and interobserver variation could not be assessed. In conclusion, ultrasound remains the corner stone of diagnosis, staging and follow up of CE cysts. MRI reproduces the ultrasound-defined features of CE better than CT. If US can not be performed due to cyst location or patient-specific reasons MRI with heavily T2-weighted series is preferable to CT. Supporting Information Checklist S1 (DOC) Click here for additional data file. Flowchart S1 (DOCX) Click here for additional data file.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Update on cystic hydatid disease.

            Cystic echinococcosis, or cystic hydatidosis, is a complex, chronic disease with a cosmopolitan distribution. In humans, its clinical spectrum ranges from asymptomatic infection to severe, rarely even fatal disease. Four approaches in clinical management exist: surgery, percutaneous techniques and drug treatment for active cysts, and the so-called watch and wait approach for inactive cysts. Allocation of patients to these treatments should be based on cyst stage, size and location, available clinical expertise and comorbidities. However, clinical decision algorithms, efficacy, relapse rates, and costs have never been properly evaluated.We review the currently available evidence for clinical decision-making and discuss ways to improve standards of care of one of the most neglected infectious diseases. Data are mostly derived from case series and small clinical trials, and treatment guidelines remain at the level of expert opinion. No single high-quality comparative clinical trial of the four treatment options is available to resolve important questions such as stage-specific allocation of treatments, adverse events and long-term relapse rates. Recent work is beginning to acknowledge this problem. Currently, four treatment modalities are available for cystic echinococcosis. The level of evidence on which clinicians have to rely is low. For the time being patients should thus be treated in referral centres. Proper comparative clinical trials are urgently needed.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Echinococcosis--an international public health challenge.

              This review aims to summarise some of the recent studies that have been undertaken on parasites of the genus Echinococcus and the diseases which they cause. Although the adult parasite, which inhabits the intestine of various carnivore species is not pathogenic, the larval or metacestode stages can be highly pathogenic, causing economic losses to livestock and various forms of echinococcosis in humans, some of which have a high fatality rate. There is growing evidence that there are at least 5 species of Echinococcus rather than the generally accepted 4 species. Within these species there are a number of genotypes or strains. This can have implications for surveillance and control. In some wealthy countries, cystic echinococcosis caused by Echinococcus granulosus has been successfully controlled or indeed eradicated. However, in most parts of the world it remains a serious threat to human health. In the former Soviet Union, the disease has rapidly increased in incidence after the end of communist administration. Human alveolar echinococcosis, caused by Echinococcus multilocularis, is more sporadic. However, in some Chinese communities there is a disturbingly high human prevalence and in Europe there has been an increase in the detection rate of E. multilocularis in animals in the last 10 years. Echinococcosis can present diagnostic challenges, particularly in the definitive host in areas of low endemicity. Much of the recent work relating to the use of coproantigen and PCR to overcome these difficulties is summarized. New ideas for controlling the parasite are becoming available and these include both the use of vaccination and the application of mathematical models to determine the most cost effective means of control. Effective measures that are affordable are vital if the parasite is to be controlled in poor countries.
                Bookmark

                Author and article information

                Journal
                Parasite
                Parasite
                EDP Sciences
                1776-1042
                2014
                December 2014
                : 21
                :
                : 65
                Article
                10.1051/parasite/2014065
                a9608c7b-e4b8-4db9-9456-359aeffd7a15
                © 2014

                This work is licensed under a Creative Commons Attribution 4.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

                History

                Parasitology,Life sciences
                Parasitology, Life sciences

                Comments

                Comment on this article