      Call for Papers: Green Renal Replacement Therapy: Caring for the Environment

      Submit here before July 31, 2024

      About Blood Purification: 3.0 Impact Factor I 5.6 CiteScore I 0.83 Scimago Journal & Country Rank (SJR)

      • Record: found
      • Abstract: found
      • Article: found

      Three-dimensional echocardiographic analysis of left ventricular function during hemodialysis.

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The effects of hemodialysis (HD) on left ventricular (LV) function have been studied by various echocardiographic techniques (M-mode, 2D echocardiography). These studies are hampered by a low accuracy of measurements because of geometric assumptions regarding LV shape. Three-dimensional echocardiography (3DE) overcomes this limitation.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography.

          We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging.

            We evaluated the accuracy and reproducibility of contrast echocardiography versus tissue harmonic imaging for measurements of left ventricular (LV) volumes and ejection fraction (EF) compared to magnetic resonance imaging (MRI). Digital echo recordings of apical LV views before and after intravenous contrast were collected from 110 consecutive patients. Magnetic resonance imaging of multiple short-axis LV sections was performed with a 1.5-T scanner. Left ventricular volumes and EF were calculated offline by method of discs. Thirty randomly selected patients were reanalyzed for intraobserver and interobserver variability. Compared with baseline, contrast echo increased feasibility for single-plane and biplane volume analysis from 87% to 100% and from 79% to 95%, respectively. The Bland-Altman analysis demonstrated volume underestimation by echo, but much less pronounced with contrast. Limits of agreement between echo and MRI narrowed significantly with contrast: from -18.1% to 8.3% to -7.7% to 4.1% (EF), from -98.2 to -11.7 ml to -59.0 to 10.7 ml (end-diastolic volume), and from -58.8 to 21.8 ml to -38.6 to 23.9 ml (end-systolic volume). Ejection fraction from precontrast echo and MRI differed by > or =10% (EF units) in 23 patients versus 0 after contrast (p < 0.001). At intraobserver and interobserver analysis, limits of agreement for EF narrowed significantly with contrast. The two-dimensional echocardiographic evaluation of LV volumes and EF in non-selected cardiac patients was found to be more accurate and reproducible when adding an intravenous contrast agent.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Prognostic value of echocardiographic indicators of left ventricular systolic function in asymptomatic dialysis patients.

              Patients with end-stage renal disease (ESRD) are at high risk for heart failure, but the prevalence and the prognostic value of asymptomatic systolic dysfunction in these patients are unknown. In this prospective cohort study, the authors have therefore assessed by echocardiography the prevalence and the prognostic value of systolic function as estimated by ejection fraction (EF), fractional shortening at endocardial level (endoFS), and at midwall (mwFS), in a cohort of 254 asymptomatic dialysis patients. Systolic dysfunction had a prevalence rate of 26% by endoFS and of 48% by mwFS. During the follow-up period, 125 patients had one or more fatal and nonfatal CV events. On multivariate COX regression analysis, the three LV systolic function indicators were independently associated with incident fatal and nonfatal CV events, and there were no differences in the predictive power of these indicators (P > 0.30). The prediction power of LV function indicators was largely independent of traditional and novel risk factors in ESRD such as C-reactive protein and asymmetric dimethyl arginine (ADMA). ADMA was significantly related with LV function indicators as well as with mortality and incident CV events, but these links were much reduced (P = NS) in models including LV function indicators. Of note, the risk of CV events was minimal in patients with normal LV mass and function, intermediate in patients with either LVH or systolic dysfunction, and maximal in patients displaying both alterations. The study of myocardial contractility by echocardiography provides prognostic information independently of LV mass and other risk factors in ESRD. Risk stratification by simple systolic function parameters may prove useful in secondary prevention strategies in these patients.
                Bookmark

                Author and article information

                Journal
                Nephron Clin Pract
                Nephron. Clinical practice
                S. Karger AG
                1660-2110
                1660-2110
                2007
                : 107
                : 2
                Affiliations
                [1 ] Department of Cardiology, Thorax Center, Rotterdam, The Netherlands. b.krenning@erasmusmc.nl
                Article
                000107553
                10.1159/000107553
                17713350
                d316824d-58e0-4321-a310-5329898f4c26
                History

                Comments

                Comment on this article