      Highly Compact Fiber Fabry-Perot Interferometer: A New Instrument Design

      research-article
      1 , 1 , 2
      The Review of scientific instruments

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This paper presents the design, construction and characterization of a new optical-fiber-based, low-finesse Fabry-Perot interferometer with a simple cavity formed by two reflecting surfaces (the end of a cleaved optical fiber and a plane, reflecting counter-surface), for the continuous measurement of displacements of several nanometers to several tens of millimeters. No beam collimation or focusing optics are required, resulting in a displacement sensor that is extremely compact (optical fiber diameter 125 μm), is surprisingly tolerant of misalignment (more than 5°), and can be used over a very wide range of temperatures and environmental conditions, including ultra-high-vacuum. The displacement measurement is derived from interferometric phase measurements using an infrared laser source whose wavelength is modulated sinusoidally at a frequency f. The phase signal is in turn derived from changes in the amplitudes of demodulated signals, at both the modulation frequency, f, and its harmonic at, 2 f coming from a photodetector that is monitoring light intensity reflected back from the cavity as the cavity length changes. Simple quadrature detection results in phase errors corresponding to displacement errors of up to 25 nm, but by using compensation algorithms discussed in this paper, these inherent non-linearities can be reduced to below 3 nm. In addition, wavelength sweep capability enables measurement of the absolute surface separation. This experimental design creates a unique set of displacement measuring capabilities not previously combined in a single interferometer.

          Related collections

          Most cited references13

          • Record: found
          • Abstract: not found
          • Article: not found

          Improved fiber‐optic interferometer for atomic force microscopy

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Overview of high performance fibre-optic sensing

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Current-induced frequency modulation in diode lasers

                Bookmark

                Author and article information

                Journal
                0405571
                7270
                Rev Sci Instrum
                Rev Sci Instrum
                The Review of scientific instruments
                0034-6748
                1089-7623
                10 April 2017
                November 2016
                01 November 2017
                : 87
                : 11
                : 115102
                Affiliations
                [1 ]National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
                [2 ]University of North Carolina at Charlotte, Charlotte, North Carolina 28223, USA
                Article
                PMC5480245 PMC5480245 5480245 nistpa856002
                10.1063/1.4964622
                5480245
                27910304
                b235baee-b931-4334-b976-aeeb29b9c3de
                History
                Categories
                Article

                Comments

                Comment on this article