21
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      POWER CONSUMPTION COMPARISON OF FIVE BUILDING ENVELOPES IN THE NORTHERN PRAIRIE CLIMATE OF MANITOBA

      research-article

      Read this article at

      ScienceOpenPublisher
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The energy efficiency of a building depends on building envelope performance. The results presented in this paper are the first of a long-term building envelope research project at the Alternative Village at the University of Manitoba in Winnipeg, Manitoba, Canada. Five test buildings were constructed using the following systems: two wood frames with fiberglass batt insulation and dense pack cellulose, one polyurethane structural insulated panels (PUR SIP), and two with the Stay in place PVC concrete form building system using 102mm and 204mm of concrete externally insulated with 102mm of expanded polystyrene foam. All of the buildings had a common foundation and roof system with a footprint of 23.8 m 2. Blower door tests were conducted to determine air tightness. Each structure was heated with an electrical resistance heater and maintained at a constant internal temperature. The thermal gradient through the wall and power consumption were monitored. The study period discussed in this report represents the main heating season from October 2011 to April 2012 consisting of 209 days. Based on the power consumption, the PUR SIP consumed the least at 2498 kWh, while the 204 mm Stay in place PVC concrete form building used the most at 2898 kWh for the same time period. The thermal gradient through the cross section of the wood frame structures was compared through the cavity insulation and at the stud. It was found that the cellulose building provided better thermal resistance along the stud when compared to the fiberglass batt insulation.

          Related collections

          Most cited references13

          • Record: found
          • Abstract: not found
          • Article: not found

          Methodology and Design of Field Experiments for Monitoring the Hygrothermal Performance of Wood Frame Enclosures

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            On the thermal buffering of naturally ventilated buildings through internal thermal mass

              Bookmark
              • Record: found
              • Abstract: not found
              • Conference Proceedings: not found

              A new measurement strategy for in situ testing of wall thermal performance

                Bookmark

                Author and article information

                Journal
                jgrb
                Journal of Green Building
                College Publishing
                1552-6100
                1943-4618
                1943-4618
                Fall 2014
                : 9
                : 4
                : 147-160
                Author notes

                1. Associate Professor, Director – The Alternative Village, Department of Biosystems Engineering, Faculty of Engineering, University of Manitoba, Rm E1-344 EITC, 75 Chancellors Circle, Winnipeg, Manitoba, Canada email: kjdick@ 123456ad.umanitoba.ca T:1-204-474-6457, F: 1-204-474-7512. Corresponding Author

                2. Graduate Student, Department of Biosystems Engineering, Faculty of Engineering, University of Manitoba email: hossein.safavian@ 123456gmail.com

                3. Research Assistant, Department of Biosystems Engineering, Faculty of Engineering, University of Manitoba email: grant.f.rayner@ 123456gmail.com

                Article
                jgb.9.4.147
                10.3992/1943-4618-9.4.147
                9ebdc28e-7f16-4df0-96eb-a277f231e9f7
                ©2014 by College Publishing. All rights reserved.
                History
                Page count
                Pages: 14
                Categories
                RESEARCH ARTICLES

                Urban design & Planning,Civil engineering,Environmental management, Policy & Planning,Architecture,Environmental engineering
                mass walls,power consumption,cellulose insulation,fiberglass insulation,polyurethane structural insulated panels

                Comments

                Comment on this article