      The King Vision™ video laryngoscope for awake intubation: series of cases and literature review.

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Intubation of patients with a supraglottic mass causing obstruction of the glottis remains a difficult problem for the experienced anesthesiologist. Awake fiberscopic endotracheal intubation is the recommended approach in such cases; however, use of a video laryngoscope for awake intubation can be an alternative to a fiberscope. Here we present two cases of awake intubation using a King Vision™ video laryngoscope in patients with a supraglottic mass, and a literature review on use of video laryngoscopes for awake intubation. After topical anesthesia and sedation with opioids, the patients were successfully intubated.

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          Awake fiberoptic or awake video laryngoscopic tracheal intubation in patients with anticipated difficult airway management: a randomized clinical trial.

          Awake flexible fiberoptic intubation (FFI) is the gold standard for management of anticipated difficult tracheal intubation. The purpose of this study was to compare awake FFI to awake McGrath® video laryngoscope, (MVL), (Aircraft Medical, Edinburgh, Scotland, United Kingdom) intubation in patients with an anticipated difficult intubation. The authors examined the hypothesis that MVL intubation would be faster than FFI. Ninety-three adult patients with anticipated difficult intubation were randomly allocated to awake FFI or awake MVL, patients were given glycopyrrolate, nasal oxygen, topical lidocaine orally, and a transtracheal injection of 100 mg lidocaine. Remifentanil infusion was administered intravenously to a Ramsay sedation score of 2-4. Time to tracheal intubation was recorded by independent assessors. The authors also recorded intubation success on the first attempt, investigators' evaluation of ease of the technique, and patients reported intubation-discomfort evaluated on a visual analog scale. Eighty-four patients were eligible for analysis. Time to tracheal intubation was median [interquartile range, IQR] 80 s [IQR 58-117] with FFI and 62 s [IQR 55-109] with MVL (P = 0.17). Intubation success on the first attempt was 79% versus 71% for FFI and MVL, respectively. The median visual analog scale score for ease of intubation was 2 (IQR 1-4) versus 1 (IQR 1-6) for FFI and MVL, respectively. The median visual analog scale score for patients' assessment of discomfort for both techniques was 2, FFI (IQR 0-3), MVL (IQR 0-4). The authors found no difference in time to tracheal intubation between awake FFI and awake MVL intubation performed by experienced anesthesiologists in patients with anticipated difficult airway.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Remifentanil target-controlled infusion vs propofol target-controlled infusion for conscious sedation for awake fibreoptic intubation: a double-blinded randomized controlled trial.

            Awake fibreoptic intubation (AFOI) is a technique used in patients with difficult airways. This study compares the suitability of remifentanil target-controlled infusion (TCI) to propofol TCI for conscious sedation during AFOI in patients with bona fide difficult airways. We recruited 24, ASA I-III patients, who were undergoing sedation for elective AFOI. Patients were randomized to one of the two groups, Group P (n=10) received propofol TCI and Group R (n=14) received remifentanil TCI. Primary outcome measures were conditions achieved at endoscopy, intubation, and post-intubation, which were graded using scoring systems. Other parameters measured were the endoscopy time, intubation time, and number of attempts at intubation. A postoperative interview was conducted to determine recall of events and level of patient satisfaction. Endoscopy scores (0-5) and intubation scores (0-5) were significantly different [Group P 3 (1-4) vs Group R 1 (0-3) P<0.0001, Group P 3 (2-4) vs Group R 1 (0-3) P<0.0001, respectively]; with much better conditions in Group R, endoscopy times and intubation times were also significantly different, being shorter in Group R (P<0.007 and P<0.023, respectively). Patient tolerance of the procedure, judged by the discomfort scores (P<0.004) and the post-intubation scores (P<0.08), was significantly better in Group R. The level of recall for events was higher in Group R. However, there were no significant differences in the patient satisfaction scores. Remifentanil TCI appears to provide better conditions for AFOI when compared with propofol TCI. The disadvantage of remifentanil in this setting may be a higher incidence of recall.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Awake Glidescope® intubation in a patient with a huge and fixed supraglottic mass -A case report-

              Intubating patients with a huge, fixed supraglottic mass causing an obstruction of the glottis is difficult to most anesthesiologists. We attempted awake fiberoptic orotracheal intubation assisted by Glidescope® Videolaryngoscope (GVL) following topical anesthesia with 4% lidocaine spray and remifentanil infusion. The glottis could not be identified by the GVL view. However, by entering toward the right side of the mass with bronchoscope, the glottis was found. Due to stiffness of the mass, we were unable to further enter the area using the bronchoscope. Alternatively, we attempted to expose the glottis by GVL blade and then successfully intubated the patient by manually pressing the cricoids cartilage. GVL is nonetheless an excellent instrument in airway management compared to fiberoptic bronchoscope for patients with a huge and fixed supraglottic mass.
                Bookmark

                Author and article information

                Journal
                Ther Clin Risk Manag
                Therapeutics and clinical risk management
                Informa UK Limited
                1176-6336
                1176-6336
                2014
                : 10
                Affiliations
                [1 ] Department of Emergency Medicine and Disaster Medicine, Medical University of Lodz, Lodz, Poland.
                Article
                tcrm-10-475
                10.2147/TCRM.S64638
                4075958
                25018634
                52d8a6a6-d241-4ef5-ba5a-f779fd434eec
                History

                airway management,awake intubation,difficult airway,video laryngoscope