13
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      A complete workflow for high-resolution spectral-stitching nanoelectrospray direct-infusion mass-spectrometry-based metabolomics and lipidomics.

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Metabolomic and lipidomic studies measure and discover metabolic and lipid profiles in biological samples, enabling a better understanding of the metabolism of specific biological phenotypes. Accurate biological interpretations require high analytical reproducibility and sensitivity, and standardized and transparent data processing. Here we describe a complete workflow for nanoelectrospray ionization (nESI) direct-infusion mass spectrometry (DIMS) metabolomics and lipidomics. After metabolite and lipid extraction from tissues and biofluids, samples are directly infused into a high-resolution mass spectrometer (e.g., Orbitrap) using a chip-based nESI sample delivery system. nESI functions to minimize ionization suppression or enhancement effects as compared with standard electrospray ionization (ESI). Our analytical technique-named spectral stitching-measures data as several overlapping mass-to-charge (m/z) windows that are subsequently 'stitched' together, creating a complete mass spectrum. This considerably increases the dynamic range and detection sensitivity-about a fivefold increase in peak detection-as compared with the collection of DIMS data as a single wide mass-to-charge (m/z ratio) window. Data processing, statistical analysis and metabolite annotation are executed as a workflow within the user-friendly, transparent and freely available Galaxy platform (galaxyproject.org). Generated data have high mass accuracy that enables molecular formulae peak annotations. The workflow is compatible with any sample-extraction method; in this protocol, the examples are extracted using a biphasic method, with methanol, chloroform and water as the solvents. The complete workflow is reproducible, rapid and automated, which enables cost-effective analysis of >10,000 samples per year, making it ideal for high-throughput metabolomics and lipidomics screening-e.g., for clinical phenotyping, drug screening and toxicity testing.

          Related collections

          Author and article information

          Journal
          Nat Protoc
          Nature protocols
          Springer Science and Business Media LLC
          1750-2799
          1750-2799
          February 2016
          : 12
          : 2
          Affiliations
          [1 ] School of Biosciences, University of Birmingham, Birmingham, UK.
          [2 ] NERC Biomolecular Analysis Facility - Metabolomics Node (NBAF-B), School of Biosciences, University of Birmingham, Birmingham, UK.
          Article
          nprot.2016.156
          10.1038/nprot.2016.156
          28079878
          579b0923-0a04-4288-a9ed-6eae0ac3b89a
          History

          Comments

          Comment on this article