1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Retracted: Software Application toward Accessible Hearing Care Assessment: Gap in Noise Test

      retraction
      Journal of Healthcare Engineering
      Hindawi

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references1

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Software Application toward Accessible Hearing Care Assessment: Gap in Noise Test

          Currently, several methods are being applied to assess auditory temporal resolution in a controlled clinical environment via the measurements of gap detection thresholds (GDTs). However, these methods face two issues: the relatively long time required to perform the gap detection test in such settings and the potential of inaccessibility to such facilities. This article proposes a fast, affordable, and reliable application-based method for the determination of GDT either inside or outside the soundproof booth. The proposed test and the acoustic stimuli were both developed using the MATLAB® programming platform. GDT is determined when the subject is able to distinguish the shortest silent gap inserted randomly in one of two segments of white noise. GDTs were obtained from 42 normal-hearing subjects inside and outside the soundproof booth. The results of this study indicated that average GDTs measured inside the booth (5.12 ± 1.02 ms) and outside (4.78 ± 1.16 ms) were not significantly different. The measured GDTs were also comparable to that reported in the literature. In addition, the GDT screening time of the proposed method was approximately 5 minutes, a screening time that is much less than that reported by the literature. Data show that the proposed application was fast and reliable to screen GDT compared to the standard method currently used in clinical settings.
            Bookmark

            Author and article information

            Contributors
            Journal
            J Healthc Eng
            J Healthc Eng
            JHE
            Journal of Healthcare Engineering
            Hindawi
            2040-2295
            2040-2309
            2023
            1 November 2023
            1 November 2023
            : 2023
            : 9894189
            Affiliations
            Article
            10.1155/2023/9894189
            10631985
            001af6bf-cb84-41a9-8672-a9f50dfaece4
            Copyright © 2023 Journal of Healthcare Engineering.

            This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

            History
            : 31 October 2023
            : 31 October 2023
            Categories
            Retraction

            Comments

            Comment on this article