6
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Morbimortalidad precoz y alejada del reemplazo valvular aórtico con prótesis mecánica y biológica durante la última década: El estándar de oro Translated title: Early and late morbidity and mortality of aortic valve replacement with mechanical or biological prostheses during the last decade: The gold standard

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Translated abstract

          Background: There is a growing interest in alternative techniques for aortic valve replacement (AVR). Therefore it is important to have updated results of conventional AYR as a valid comparative standard. Aim: To evaluate both perioperative and ¡ate morbidity and mortality in patients undergoing conventional AVR, with either mechanical (RVAm) or biological (RVAb) prostheses. Patients and methods: Retrospective review of medical records and operative protocols of patients undergoing AVR between January 1995 and December 2005. Patients with previous cardiac surgery, aortic balloonplasty or simultaneous cardiovascular procedures were excluded. Results: During the study period, 788 patients underwent AVR and 317 met the inclusion criteria. Of the latter, 175patients aged 13 to 83years (63% males) were subjected to AVRm and 142patients aged 49 to 87 years (64% males), were subjected to AVRb. Five (1.6%) patients died during the perioperative period (one AVRm and four AVRb). All were older than 65years. Perioperative complications were recorded in 29 and 25% of patients in AVRm and AVRb groups, respectively (NS). During a median follow-up of six years, complications were recorded in 12 and 4% of patients in AVRm and AVRb groups, respectively (p <0.05). The actuarial survival for AVRm group at 1, 5 and 10years, was 96, 92 and 87%, respectively. The figures for AVRb group were 95, 86 and 83%, respectively (NS). The 10 year reintervention free survival was 97% for the AVRm group and 84% for the AVRb (p <0.05). Conclusions: Perioperative mortality and rates of complications of AVR in this series of patients are low, which compares favorably with other series (Rev Méd Chile 2009; 137:1153-62).

          Related collections

          Most cited references64

          • Record: found
          • Abstract: found
          • Article: not found

          Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

          The design of a percutaneous implantable prosthetic heart valve has become an important area for investigation. A percutaneously implanted heart valve (PHV) composed of 3 bovine pericardial leaflets mounted within a balloon-expandable stent was developed. After ex vivo testing and animal implantation studies, the first human implantation was performed in a 57-year-old man with calcific aortic stenosis, cardiogenic shock, subacute leg ischemia, and other associated noncardiac diseases. Valve replacement had been declined for this patient, and balloon valvuloplasty had been performed with nonsustained results. With the use of an antegrade transseptal approach, the PHV was successfully implanted within the diseased native aortic valve, with accurate and stable PHV positioning, no impairment of the coronary artery blood flow or of the mitral valve function, and a mild paravalvular aortic regurgitation. Immediately and at 48 hours after implantation, valve function was excellent, resulting in marked hemodynamic improvement. Over a follow-up period of 4 months, the valvular function remained satisfactory as assessed by sequential transesophageal echocardiography, and there was no recurrence of heart failure. However, severe noncardiac complications occurred, including a progressive worsening of the leg ischemia, leading to leg amputation with lack of healing, infection, and death 17 weeks after PHV implantation. Nonsurgical implantation of a prosthetic heart valve can be successfully achieved with immediate and midterm hemodynamic and clinical improvement. After further device modifications, additional durability tests, and confirmatory clinical implantations, PHV might become an important therapeutic alternative for the treatment of selected patients with nonsurgical aortic stenosis.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Aortic Stenosis

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The problem of valve prosthesis-patient mismatch.

              Valve prostheses have played an important part in the past two decades in the management of patients with valvular heart disease. However, many of the devices used in valve replacement have introduced new clinical problems. This paper deals with some of the problems associated with valve replacement, including one not previously emphasized--valve prosthesis-patient mismatch, which may cause obstruction to ventricular outflow and/or inflow.
                Bookmark

                Author and article information

                Journal
                rmc
                Revista médica de Chile
                Rev. méd. Chile
                Sociedad Médica de Santiago (Santiago, , Chile )
                0034-9887
                September 2009
                : 137
                : 9
                : 1153-1162
                Affiliations
                [01] Santiago orgnamePontificia Universidad Católica de Chile orgdiv1Facultad de Medicina orgdiv2Departamento de Enfermedades Cardiovasculares Chile
                Article
                S0034-98872009000900003 S0034-9887(09)13700903
                10.4067/S0034-98872009000900003
                001ba6f1-3245-4768-b79d-5abdfb13022e

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                : 24 July 2009
                : 09 January 2009
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 39, Pages: 10
                Product

                SciELO Chile

                Categories
                ARTICULOS DE INVESTIGACION

                Cardiovascular surgical procedures,Aortic valve,Thoracic surgery

                Comments

                Comment on this article