21
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      A comparative analysis using flowmeter, laser-Doppler |spectrophotometry, and indocyanine green-videoangiography for detection of vascular stenosis in free flaps

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The effects of gradual vascular occlusion on the blood supply of perfused areas are poorly described. Information relating to the comparison of flap monitoring techniques is lacking. Varying stenotic conditions (0%, 25%, 50%, 75% and 100%) were generated on purpose at the A. and V. femoralis in the rat model. Analyses included flowmeter, simultaneous laser-Doppler flowmetry and tissue spectrophotometry (O2C) and indocyanine green- (ICG-) videoangiography with integrated FLOW 800 tool. A Random Forests prediction model was used to analyse the importance of each method to diagnose the stenotic conditions. The ability to discriminate and to accurately estimate the probability of stenosis was assessed by Receiver Operating Characteristic (ROC) curves and calibration plots. Blood flow changes for all modalities were described in detail. Flowmeter displayed earliest a linear decrease as a result of increasing stenosis. A stenosis of 50% degrees was most difficult to detect correctly. The combination of flowmeter and ICG-videoangiography showed high diagnostic power for each stenotic situation (area under the ROC > 0.79). Flowmeter and ICG-videoangiography showed to be most relevant in detection of varying stenotic conditions and may change the clinical outcome. The O2C showed less effect on varying stenotic situations as the only surface monitoring device.

          Related collections

          Most cited references40

          • Record: found
          • Abstract: found
          • Article: not found

          Near-infrared indocyanine green video angiography: a new method for intraoperative assessment of vascular flow.

          We report our initial clinical experience with a new method for intraoperative blood flow assessment. The purposes of the study were to assess the use of indocyanine green (ICG) video angiography in neurovascular cases, to assess the handling and image quality, to compare the findings with postoperative angiographic results, and to evaluate the clinical value of the method in a preliminary feasibility study. Fourteen patients with aneurysms (n = 12) or spinal (n = 1) or intracranial (n = 1) dural fistulae were included. Before and/or after aneurysm or dural fistula occlusion, ICG (25 mg) was injected intravenously. A near-infrared laser excitation light source (lambda = 780 nm) illuminated the operating field. The intravascular fluorescence of ICG (maximal lambda = 835 nm) was recorded by a nonintensified video camera, with optical filtering to block ambient and laser light for collection of only ICG-induced fluorescence. A total of 21 investigations were performed for 14 patients. For the 17 successful ICG video angiographic investigations, image quality and resolution were excellent, allowing intraoperative real-time assessment of the cerebral circulation. ICG angiographic results could be divided into arterial, capillary, and venous phases, comparable to those observed with digital subtraction angiography. In all cases, the postoperative angiographic results corresponded to the intraoperative ICG video angiographic findings. In three cases, the information provided by intraoperative ICG angiography significantly changed the surgical procedure. ICG video angiography is simple and provides real-time information on the patency of arterial and venous vessels of all relevant diameters, including small and perforating arteries (<0.5 mm), and the visible aneurysm sac. It may be a useful adjunct to improve the quality of neurovascular procedures and to document the intraoperative vascular flow.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Timing of presentation of the first signs of vascular compromise dictates the salvage outcome of free flap transfers.

            Microsurgical free tissue transfer has become a reliable technique. Nevertheless, 5 to 25 percent of transferred flaps require re-exploration due to circulatory compromise. This study was conducted to evaluate the timing of occurrence of flap compromise following free tissue transfer, and its correlation with salvage outcome. Between January of 2002 and June of 2003, 1142 free flap procedures were performed and 113 flaps (9.9 percent) received re-exploration due to compromise. All patients were cared for in the microsurgical intensive care unit for 5 days. Through a retrospective review, timing of presentation of compromise was identified and correlated with salvage outcome. Seventy-two flaps (63.7 percent) were completely salvaged and 23 (20.4 percent) were partially salvaged. Eighteen flaps (15.9 percent) failed completely. Ninety-three flaps (82.3 percent) presented with circulatory compromise within 24 hours; 108 (95.6 percent) presented with circulatory compromise within 72 hours, and 92 flaps (85.2 percent) were salvaged within this period. One out of the three flaps presenting with compromise 1 week postoperatively was salvaged. Flaps presenting with compromise upon admission to the microsurgical intensive care unit had significantly lower complete salvage rates as compared with those without immediate abnormal signs (40.9 percent versus 69.2 percent, p = 0.01). The time of presentation of flap compromise is a significant predictor of flap salvage outcome. Intensive flap monitoring at a special microsurgical intensive care unit by well-trained nurses and surgeons allows for early detection of vascular compromise, which leads to better outcomes.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              A new variable importance measure for random forests with missing data

                Bookmark

                Author and article information

                Contributors
                Lucas.Ritschl@tum.de
                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group UK (London )
                2045-2322
                22 January 2020
                22 January 2020
                2020
                : 10
                : 939
                Affiliations
                [1 ]Department of Oral and Maxillofacial Surgery, Malteser Kliniken Rhein-Ruhr, Krefeld-Uerdingen, Germany
                [2 ]ISNI 0000000123222966, GRID grid.6936.a, Institute of Medical Informatics, Statistics and Epidemiology, School of Medicine, , Technical University of Munich, ; Munich, Germany
                [3 ]Department of Oral and Maxillofacial Surgery, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
                [4 ]Leeds Teaching Hospitals, St James Institute of Oncology and Leeds Dental Institute, Munich, Germany
                Author information
                http://orcid.org/0000-0003-3561-1277
                http://orcid.org/0000-0003-3367-7096
                http://orcid.org/0000-0002-9002-3892
                Article
                57777
                10.1038/s41598-020-57777-2
                6976589
                31969630
                005582ef-b5bc-4a32-9deb-f846fadc0166
                © The Author(s) 2020

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 19 November 2018
                : 3 January 2020
                Categories
                Article
                Custom metadata
                © The Author(s) 2020

                Uncategorized
                experimental models of disease,surgical oncology
                Uncategorized
                experimental models of disease, surgical oncology

                Comments

                Comment on this article