      Volumetric and Spatial Accuracy of Computed Tomography Perfusion Estimated Ischemic Core Volume in Patients With Acute Ischemic Stroke.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background and Purpose- The volume of estimated ischemic core using computed tomography perfusion (CTP) imaging can identify ischemic stroke patients who are likely to benefit from reperfusion, particularly beyond standard time windows. We assessed the accuracy of pretreatment CTP estimated ischemic core in patients with successful endovascular reperfusion. Methods- Patients from the HERMES (Highly Effective Reperfusion Evaluated in Multiple Endovascular Stroke Trials) and EXTEND-IA TNK (Tenecteplase Versus Alteplase Before Endovascular Therapy for Ischemic Stroke) databases who had pretreatment CTP, >50% angiographic reperfusion, and follow-up magnetic resonance imaging at 24 hours were included. Ischemic core volume on baseline CTP data was estimated using relative cerebral blood flow <30% (RAPID, iSchemaView). Follow-up diffusion magnetic resonance imaging was registered to CTP, and the diffusion lesion was outlined using a semiautomated algorithm. Volumetric and spatial agreement (using Dice similarity coefficient, average Hausdorff distance, and precision) was assessed, and expert visual assessment of quality was performed. Results- In 120 patients, median CTP estimated ischemic core volume was 7.8 mL (IQR, 1.8-19.9 mL), and median diffusion lesion volume at 24 hours was 30.8 mL (IQR, 14.9-67.6 mL). Median volumetric difference was 4.4 mL (IQR, 1.2-12.0 mL). Dice similarity coefficient was low (median, 0.24; IQR, 0.15-0.37). The median precision (positive predictive value) of 0.68 (IQR, 0.40-0.88) and average Hausdorff distance (median, 3.1; IQR, 1.8-5.7 mm) indicated reasonable spatial agreement for regions estimated as ischemic core at baseline. Overestimation of total ischemic core volume by CTP was uncommon. Expert visual review revealed overestimation predominantly in white matter regions. Conclusions- CTP estimated ischemic core volumes were substantially smaller than follow-up diffusion-weighted imaging lesions at 24 hours despite endovascular reperfusion within 2 hours of imaging. This may be partly because of infarct growth. Volumetric CTP core overestimation was uncommon and not related to imaging-to-reperfusion time. Core overestimation in white matter should be a focus of future efforts to improve CTP accuracy.

          Related collections

          Author and article information

          Journal
          Stroke
          Stroke
          Ovid Technologies (Wolters Kluwer Health)
          1524-4628
          0039-2499
          Oct 2018
          : 49
          : 10
          Affiliations
          [1 ] From the Department of Medicine and Neurology, Melbourne Brain Centre at the Royal Melbourne Hospital (J.W.H., N.Y., G.S., S.M.D., B.C.V.C.), University of Melbourne, Parkville, Australia.
          [2 ] Department of Radiology and Nuclear Medicine (J.W.H., H.A.M., C.B.L.M.M.), Amsterdam UMC (Universitair Medische Centra), University of Amsterdam, the Netherlands.
          [3 ] Department of Biomedical Engineering and Physics (H.A.M.), Amsterdam UMC (Universitair Medische Centra), University of Amsterdam, the Netherlands.
          [4 ] The Florey Institute of Neuroscience and Mental Health (N.Y., G.A.D.), University of Melbourne, Parkville, Australia.
          [5 ] Neurovascular Imaging Research Core, Department of Neurology (D.S.L.), University of California at Los Angeles.
          [6 ] Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, the Netherlands (A.v.d.L.).
          [7 ] Department of Neurology (Y.B.R.), Amsterdam UMC (Universitair Medische Centra), University of Amsterdam, the Netherlands.
          [8 ] Department of Radiology (W.v.Z.), Cardiovascular Research Institute (CARIM), Maastricht University Medical Center, the Netherlands.
          [9 ] Department of Neurology (R.J.v.O.), Cardiovascular Research Institute (CARIM), Maastricht University Medical Center, the Netherlands.
          [10 ] Department of Radiology, University of Calgary, Foothills Hospital, AB, Canada (M.G.).
          [11 ] Department of Neurology (J.L.S.), University of California at Los Angeles.
          [12 ] Department of Neurology, Stroke Institute, University of Pittsburgh Medical Center, CA (T.G.J.).
          [13 ] Stanford Stroke Center, Stanford University, CA (G.W.A.).
          [14 ] Department of Neuroscience, Hospital Germans Trias i Pujol, Universitat Autònoma de Barcelona, Spain (A.D.).
          [15 ] Department of Clinical Neurosciences, Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Foothills Hospital, AB, Canada (M.D.H., A.M.D.).
          [16 ] Department of Diagnostic and Interventional Neuroradiology, INSERM U 947 (S.B.), University of Lorraine and University Hospital of Nancy, France.
          [17 ] INSERM CIC-EC 1433 Clinical Epidemiology (F.G.), University of Lorraine and University Hospital of Nancy, France.
          [18 ] Institute of Neuroscience and Psychology, University of Glasgow, Queen Elizabeth University Hospital, Scotland, United Kingdom (K.W.M.).
          [19 ] Institute of Neuroscience, Newcastle University (P.W.), Newcastle upon Tyne Hospitals NHS Foundation Trust, United Kingdom.
          [20 ] Department of Neuroradiology (P.W.), Newcastle upon Tyne Hospitals NHS Foundation Trust, United Kingdom.
          [21 ] Department of Radiology, Royal Melbourne Hospital, University of Melbourne, Australia (P.J.M.).
          Article
          10.1161/STROKEAHA.118.020846
          30355095
          00ccdb40-70c9-44a3-a13b-6b3cd33126d0
          History

          cerebral infarction,tomography, X-ray computed,thrombectomy,tenecteplase,reperfusion,magnetic resonance imaging

          Comments

          Comment on this article