8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Hyaluronic acid coated poly-ɛ-caprolactone nanospheres deliver high concentrations of cyclosporine A into the cornea

      , , , , , , ,
      Experimental Eye Research
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The objective of this study was to determine cyclosporine A (Cy A) levels in ocular tissues and fluids after topical administration of poly-epsilon-caprolactone (PCL)/benzalkonium chloride (BKC) nanospheres and hyaluronic acid (HA) coated PCL/BKC nanospheres onto healthy rabbit corneas. Nanospheres were prepared by nanoprecipitation and purified by gradient-rate centrifugation. Cy A (0.1%) in either castor oil solution (group 1), PCL/BKC nanosphere formulation (group 2) or HA coated PCL/BKC nanosphere formulation (group 3) was instilled onto rabbit corneas. Tear samples were adsorbed onto Schirmer tear strips. Cy A concentrations of fluid (blood, aqueous humor, tear) and specimen extracts (cornea, conjunctiva, iris/ciliary body) were determined by high performance liquid chromatography-mass spectrometry (LC-MS). The mean corneal Cy A concentration obtained at 0.5, 1, 2, 4, 8 and 24h following instillation of the formulations ranged between 0.12 and 1.2 ng/mg tissue for group 1, 5.9-15.5 ng/mg tissue for group 2 and 11.4-23.0 ng/mg for group 3 (one-way analysis of variance (ANOVA) and pairwise tests (SNK (Student-Newman-Keuls) and Tukey); p<0.05). Conjunctival Cy A levels of group 2 and 3 were not significantly different at any of the time points tested. However, there was a significant difference between Cy A concentration of castor oil formulation and that of PCL/BKC nanosphere formulation at 1 and 8h (p<0.05). The mean iris/ciliary body concentrations obtained with the three formulations were not significantly different at any time point with the exception of group 2 levels being higher than those of groups 1 and 3 at 1h (p<0.05). The lowest ocular tear Cy A concentrations (16-114 ng/ml) were found following the instillation of HA coated PCL/BKC nanoparticles (group 3) during the time period tested. Cy A loaded PCL/BKC and HA coated PCL/BKC nanospheres are able to achieve high levels of Cy A in the cornea that is 10-15-fold higher than that is achieved with Cy A solution in castor oil. Nanosphere formulation and HA may play an important role in delivering high levels of cyclosporine A into the cornea.

          Related collections

          Author and article information

          Journal
          Experimental Eye Research
          Experimental Eye Research
          Elsevier BV
          00144835
          September 2008
          September 2008
          : 87
          : 3
          : 162-167
          Article
          10.1016/j.exer.2008.04.002
          18675411
          036345ce-a4db-402e-876b-378a9f9e9d36
          © 2008

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article