      Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures.

      The International journal of prosthodontics
      Bicuspid, Bite Force, Computer Simulation, Cuspid, Dental Abutments, Dental Implants, Dental Materials, chemistry, Dental Prosthesis, Implant-Supported, Denture Design, Denture Liners, Denture Retention, Denture, Complete, Upper, Denture, Overlay, Elasticity, Finite Element Analysis, Humans, Imaging, Three-Dimensional, Materials Testing, Maxilla, physiology, Models, Biological, Osseointegration, Stress, Mechanical, Surface Properties

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The purpose of this study was to examine the effect of stress-breaking attachments at the connections between maxillary palateless overdentures and implants. Three-dimensional finite element models were used to reproduce an edentulous human maxilla with an implant-retained overdenture. Two-implant models (in the canine tooth positions on both sides) and four-implant models (in the canine and second premolar tooth positions on both sides) were examined. Stress-breaking material connecting the implants and denture was included around each abutment. Axial loads of 100 N were applied to the occlusal surface at the left first molar tooth positions. In each model, the influence of the stress-breaking attachments was compared by changing the elastic modulus from 1 to 3,000 MPa and the thickness of the stress-breaking material from 1 to 3 mm. Maximum stress at the implant-bone interface and stress at the cortical bone surface just under the loading point were calculated. In all models, maximum stress at the implant-bone interface with implants located in the canine tooth position was generated at the peri-implant bone on the loading side. As the elastic modulus of the stress-breaking materials increased, the stress increased at the implant-bone interface and decreased at the cortical bone surface. Moreover, stress at the implant-bone interface with 3-mm-thick stress-breaking material was smaller than that with 1-mm-thick material. Within the limitations of this experiment, stress generated at the implant-bone interface could be controlled by altering the elastic modulus and thickness of the stress-breaking materials.

          Related collections

          Author and article information

          Comments

          Comment on this article