      Comparison of spontaneous vs. metronome-guided breathing on assessment of vagal modulation using RR variability.

      American Journal of Physiology - Heart and Circulatory Physiology
      Adult, Aged, Coronary Disease, diagnosis, physiopathology, Electrocardiography, Female, Heart Rate, physiology, Humans, Male, Middle Aged, Respiration, Sinoatrial Node, innervation, Vagus Nerve

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          R-R interval variability (RR variability) is increasingly being used as an index of autonomic activity. High-frequency (HF) power reflects vagal modulation of the sinus node. Since vagal modulation occurs at the respiratory frequency, some investigators have suggested that HF power cannot be interpreted unless the breathing rate is controlled. We hypothesized that HF power during spontaneous breathing would not differ significantly from HF power during metronome-guided breathing. We measured HF power during spontaneous breathing in 20 healthy subjects and 19 patients with heart disease. Each subject's spontaneous breathing rate was determined, and the calculation of HF power was repeated with a metronome set to his or her average spontaneous breathing rate. There was no significant difference between the logarithm of HF power measured during spontaneous and metronome-guided breathing [4.88 +/- 0.29 vs. 5.29 +/- 0.30 ln(ms(2)), P = 0.32] in the group as a whole and when patients and healthy subjects were examined separately. We did observe a small (9.9%) decrease in HF power with increasing metronome-guided breathing rates (from 9 to 20 breaths/min). These data indicate that HF power during spontaneous and metronome-guided breathing differs at most by very small amounts. This variability is several logarithmic units less than the wide discrepancies observed between healthy subjects and cardiac patients with a heterogeneous group of cardiovascular disorders. In addition, HF power is relatively constant across the range of typical breathing rates. These data indicate that there is no need to control breathing rate to interpret HF power when RR variability (and specifically HF power) is used to identify high-risk cardiac patients.

          Related collections

          Author and article information

          Journal
          11179058
          10.1152/AJPHEART.2001.280.3.H1145

          Chemistry
          Adult,Aged,Coronary Disease,diagnosis,physiopathology,Electrocardiography,Female,Heart Rate,physiology,Humans,Male,Middle Aged,Respiration,Sinoatrial Node,innervation,Vagus Nerve

          Comments

          Comment on this article