5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Comparison of outcomes of laser refractive surgery (LRS) alone and LRS with laser asymmetric keratectomy in patients with myopia : A retrospective study

      research-article
      , MD, PhD a , , MD, PhD b ,
      Medicine
      Lippincott Williams & Wilkins
      laser asymmetric keratectomy, laser refractive surgery, myopia

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To compare and analyze the postoperative 1-year outcomes of laser refractive surgery (LRS) alone vs LRS with laser asymmetric keratectomy (LAK), in patients with myopia, for preventing and resolving LRS complications.

          This retrospective study compared the preoperative and 1-year postoperative outcomes between the control and comparison groups using a sum of deviations in corneal thickness in 4 directions >80 μm. The control group included 41 patients with myopia (41 eyes) who underwent LRS. The comparison group included 33 patients (33 eyes) who received LAK-linked LRS. Age, spherical equivalent (SE), sphere, cylinder, uncorrected distance visual acuity (UDVA), pupil size, kappa angle, central corneal thickness, corneal irregularity in the 3.0 mm zone on Orbscan maps (SUM), distance between the maximum posterior elevation (best-fit-sphere) and the visual axis (DISTANCE), postoperative blurring scores, frequency of postoperative myopic regression, and efficiency index were compared.

          Preoperative age ( P = .198), SE ( P = .686), sphere ( P = .562), cylinder ( P = .883), UDVA ( P = .139), pupil size ( P = .162), kappa angle ( P = .807), central corneal thickness ( P = .738), corneal irregularity ( P = .826), SUM ( P = .774), and DISTANCE ( P = .716) were similar between the 2 groups. The 1-year postoperative SE ( P = .024), sphere ( P = .022), corneal irregularity ( P = .033), SUM ( P = .000), DISTANCE ( P = .04), blurring scores ( P = .000), and frequency of postoperative myopic regression ( P = .004) were significantly decreased in the comparison group compared to the control group. UDVA ( P = .014) and the efficiency index ( P = .035) were higher in the comparison group.

          LAK with LRS improved corneal symmetry by reducing the SUM and DISTANCE. UDVA and efficiency index were also improved and blurring and myopic regression were reduced postoperatively.

          Related collections

          Most cited references31

          • Record: found
          • Abstract: found
          • Article: not found

          Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes.

          To compare the biomechanical properties of normal, post-laser in situ keratomileusis (LASIK), and keratoconic corneas evaluated by corneal hysteresis and the corneal resistance factor measured with the Reichert Ocular Response Analyzer (ORA). Instituto Oftalmológico de Alicante, Vissum, Alicante, Spain. Two hundred fifty eyes were divided into 3 groups: normal (control group), post-LASIK, and keratoconus. The corneal biomechanical properties were measured with the ORA, which uses a dynamic bidirectional applanation process. The main outcome measures were intraocular pressure, corneal hysteresis, and the corneal resistance factor. The control group had 165 eyes; the LASIK group, 65 eyes; and the keratoconus group, 21 eyes. In the control group, the mean corneal hysteresis value was 10.8 mm Hg +/- 1.5 (SD) and the mean corneal resistance factor, 11.0 +/- 1.6 mm Hg. The corneal hysteresis value was lower in older eyes, and the difference between the youngest age group (9 to 14 years) and oldest age group (60 to 80 years) was statistically significant (P = .01, t test). One month after LASIK, corneal hysteresis and the corneal resistance factor decreased significantly, from 10.44 to 9.3 mm Hg and from 10.07 to 8.13 mm Hg, respectively. In the keratoconus group, the mean corneal hysteresis was 7.5 +/- 1.2 mm Hg and the mean corneal resistance factor, 6.2 +/- 1.9 mm Hg. There were statistically significant differences in both biomechanical parameters between keratoconic eyes and post-LASIK eyes (P<.001, t test). The corneal hysteresis and corneal resistance factor values were significantly lower in keratoconic eyes than in post-LASIK eyes. Future work is needed to determine whether these differences are useful in detecting keratoconus when other diagnostic tests are equivocal.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Biomechanics of corneal ectasia and biomechanical treatments.

            Many algorithms exist for the topographic/tomographic detection of corneas at risk for post-refractive surgery ectasia. It is proposed that the reason for the difficulty in finding a universal screening tool based on corneal morphologic features is that curvature, elevation, and pachymetric changes are all secondary signs of keratoconus and post-refractive surgery ectasia and that the primary abnormality is in the biomechanical properties. It is further proposed that the biomechanical modification is focal in nature, rather than a uniform generalized weakening, and that the focal reduction in elastic modulus precipitates a cycle of biomechanical decompensation that is driven by asymmetry in the biomechanical properties. This initiates a repeating cycle of increased strain, stress redistribution, and subsequent focal steepening and thinning. Various interventions are described in terms of how this cycle of biomechanical decompensation is interrupted, such as intrastromal corneal ring segments, which redistribute the corneal stress, and collagen crosslinking, which modifies the basic structural properties.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis.

              To understand and quantify intraocular pressure (IOP) measurement errors introduced by corneal variables during applanation tonometry using a cornea biomechanical model. Department of Ophthalmology, Biomedical Engineering Center, The Ohio State University, Columbus, Ohio, USA. The model assumed an overall resultant pressure that was based on the summation of the applanation pressure, the true IOP, and the surface tension caused by the tear film to determine the final deformation of the corneal apex during IOP measurement. Corneal resistance was varied according to the cornea's biomechanical properties, thickness, and curvature, and the effect of each variable on the accuracy of IOP tonometry readings was examined quantitatively. The model demonstrated that tonometry readings do not always reflect true IOP values. They deviate when corneal thickness, curvature, or biomechanical properties vary from normal values. Based on the model, predicted IOP readings have a 2.87 mm Hg range resulting from the variation in the corneal thickness in the normal population and a 1.76 mm Hg range from the variation in the corneal radius of curvature. Considering that Young's modulus of the corneal varies from 0.1 to 0.9 MPa in the normal population, the model predicts tonometry IOP readings will have a range of 17.26 mm Hg because of the variation in this corneal biomechanical parameter alone. The simulation based on the model demonstrated quantitatively that variations in each corneal variable cause errors in tonometry IOP readings. The simulation results indicate that differences in corneal biomechanics across individuals may have greater impact on IOP measurement errors than corneal thickness or curvature.
                Bookmark

                Author and article information

                Journal
                Medicine (Baltimore)
                Medicine (Baltimore)
                MEDI
                Medicine
                Lippincott Williams & Wilkins (Hagerstown, MD )
                0025-7974
                1536-5964
                09 April 2021
                09 April 2021
                : 100
                : 14
                : e25366
                Affiliations
                [a ]Kim's Eye Hospital, Division of Cornea,Cataract, and Refractive Surgery. Konyang University School of Medicine. Youngdeungpo-gu, Seoul
                [b ]Woori Eye Clinic, Seo-Ku Daejon, Republic of Korea.
                Author notes
                []Correspondence: Byung Moo Min, Woori Eye Clinic, Affiliated Clinical Professor, Department of Ophthalmology, Yonsei University School of Medicine, 219 DaedukDae-Ro (Dunsan dong), Seo-Ku Daejon, 35229, Republic of Korea (e-mail: bmin8275@ 123456naver.com ).
                Author information
                http://orcid.org/0000-0003-1134-8945
                Article
                MD-D-20-05356 25366
                10.1097/MD.0000000000025366
                8036046
                33832118
                062cc45b-378c-4153-8637-3d3e7b81624a
                Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc.

                This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0

                History
                : 10 June 2020
                : 2 February 2021
                : 11 March 2021
                Categories
                3700
                Research Article
                Quality Improvement Study
                Custom metadata
                TRUE

                laser asymmetric keratectomy,laser refractive surgery,myopia

                Comments

                Comment on this article