      In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography

      research-article

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This study sought to compare lumen dimensions as assessed by 3D quantitative coronary angiography (QCA) and by intravascular ultrasound (IVUS) or optical coherence tomography (OCT), and to assess the association of the discrepancy with vessel curvature. Coronary lumen dimensions often show discrepancies when assessed by X-ray angiography and by IVUS or OCT. One source of error concerns a possible mismatch in the selection of corresponding regions for the comparison. Therefore, we developed a novel, real-time co-registration approach to guarantee the point-to-point correspondence between the X-ray, IVUS and OCT images. A total of 74 patients with indication for cardiac catheterization were retrospectively included. Lumen morphometry was performed by 3D QCA and IVUS or OCT. For quantitative analysis, a novel, dedicated approach for co-registration and lumen detection was employed allowing for assessment of lumen size at multiple positions along the vessel. Vessel curvature was automatically calculated from the 3D arterial vessel centerline. Comparison of 3D QCA and IVUS was performed in 519 distinct positions in 40 vessels. Correlations were r = 0.761, r = 0.790, and r = 0.799 for short diameter (SD), long diameter (LD), and area, respectively. Lumen sizes were larger by IVUS ( P < 0.001): SD, 2.51 ± 0.58 mm versus 2.34 ± 0.56 mm; LD, 3.02 ± 0.62 mm versus 2.63 ± 0.58 mm; Area, 6.29 ± 2.77 mm 2 versus 5.08 ± 2.34 mm 2. Comparison of 3D QCA and OCT was performed in 541 distinct positions in 40 vessels. Correlations were r = 0.880, r = 0.881, and r = 0.897 for SD, LD, and area, respectively. Lumen sizes were larger by OCT ( P < 0.001): SD, 2.70 ± 0.65 mm versus 2.57 ± 0.61 mm; LD, 3.11 ± 0.72 mm versus 2.80 ± 0.62 mm; Area 7.01 ± 3.28 mm 2 versus 5.93 ± 2.66 mm 2. The vessel-based discrepancy between 3D QCA and IVUS or OCT long diameters increased with increasing vessel curvature. In conclusion, our comparison of co-registered 3D QCA and invasive imaging data suggests a bias towards larger lumen dimensions by IVUS and by OCT, which was more pronounced in larger and tortuous vessels.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.

          A computer-assisted technique has been developed to assess absolute coronary arterial dimensions from 35 mm cineangiograms. The boundaries of optically magnified and video-digitized coronary segments and the intracardiac catheter are defined by automated edge-detection techniques. Contour positions are corrected for pincushion distortion. The accuracy and precision of the edge detection procedure as assessed from cinefilms of contrast-filled acrylate (Perspex) models were -30 and 90 micrometers, respectively. The variability of the analysis procedure itself in terms of absolute arterial dimensions was less than 0.12 mm, and in terms of percentage arterial narrowing for coronary obstructions less than 2.74%. Short-, medium-, and long-term variability measurements were assessed from repeated coronary angiographic examinations performed 5 min, 1 hr, and 90 days apart, respectively. For all studies the mean differences in absolute diameters were less than 0.13 mm. The variability in obstruction diameter ranged from 0.22 mm for the best-controlled study (medium-term) to 0.36 mm for the least-controlled study (long-term); variability in reference diameter ranged from 0.15 to 0.66 mm, respectively. It is concluded that the biological variations are a source of major concern and that further attempts toward standardization of the angiographic procedure are seriously needed.
            • Record: found
            • Abstract: found
            • Article: not found

            Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial).

            Drug-eluting stent failures were associated with various clinical factors. However, the clinical impact of stent deployment technique was unknown. This study was designed to evaluate the frequency and impact of suboptimal percutaneous coronary intervention on long-term outcomes of 1,557 patients treated with sirolimus-eluting stents (SESs) in 41 US hospitals. All steps of the interventional procedure were scrutinized by an independent core laboratory to determine the occurrence of geographic miss (GM). GM included longitudinal (LGM; injured or diseased segment not covered by SES) or axial GM (balloon-artery size ratio 1.3) mismatches. Patients with and without GM were stratified (GM vs no-GM group). Patients, investigators, and the independent clinical event adjudication committee were blind to study group assignments. The primary end point was 1-year target-vessel revascularization (TVR) rate. Incidences and predictors of GM and safety outcomes were secondary end points. GM occurred in 943 patients (66.5%): 47.6% had LGM, 35.2% had axial GM, and 16.5% had both. One-year TVR rates were 5.1% in the GM group versus 2.5% in the no-GM group (p=0.025). TVR was 6.1% in the LGM versus 2.6% in the no-LGM subgroups (p=0.001). The association of GM with 1-year TVR was independent of clinical or anatomic factors (hazard ratio 2.0, 95% confidence interval 1.0 to 4.02, p=0.05). There was a 3-fold increase in myocardial infarction rates associated with GM (2.4% vs 0.8%; p=0.04). In conclusion, GM occurred frequently during SES implantation and was associated with increased risk of TVR and myocardial infarction at 1 year. These results emphasized the need for improvement in contemporary percutaneous coronary intervention practices and technologies.
              • Record: found
              • Abstract: found
              • Article: not found

              First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography.

              The objective of this study is to evaluate the feasibility and safety of imaging human coronary arteries in vivo by optical frequency domain imaging (OFDI) in comparison to intravascular ultrasound (IVUS). OFDI has been recently developed to overcome the limitations of conventional time-domain optical coherence tomography (OCT), namely the need for proximal balloon occlusion. The Terumo-OFDI system is capable of acquiring images with high-speed automated pullback (up to 40 mm/sec) and requires only a short injection (3-4 sec) of small amount of x-ray contrast (9-16 ml). Nineteen patients who underwent stent implantation were enrolled. IVUS/OFDI were performed before and after stenting. The incidences of any adverse event and angiographic adverse findings were recorded. Lumen area (LA) was measured by IVUS and OFDI at 1 mm intervals in the stented segments (n=19) as well as in the proximal, distal, and to-be-stented segments (n=40). In addition, lumen area in the stented segment was also measured by edge (E-) and video-densitometric (VD-) quantitative coronary angiography (QCA). The OFDI images were obtained without any adverse event related to imaging procedures. Post stenting (n=19), minimal LA (MLA) measured by OFDI (5.84 ± 1.89 mm2) was larger than that of E-QCA (4.16 ± 1.46 mm2, p<0.001) and VD-QCA (4.92 ± 1.55 mm2, p<0.05). It was smaller than IVUS-MLA (6.26 ± 2.01 mm2, N.S.) but the correlation between the two measurements was highly significant (R2=0.82, p<0.001). The OFDI imaging is feasible both before and after stenting and has a promising safety profile. The OFDI provided clear high resolution images and robust lumen measurements.

                Author and article information

                Contributors
                S.T.Tu@lumc.nl
                bxu@citmd.com
                Journal
                Int J Cardiovasc Imaging
                Int J Cardiovasc Imaging
                The International Journal of Cardiovascular Imaging
                Springer Netherlands (Dordrecht )
                1569-5794
                1875-8312
                20 January 2012
                20 January 2012
                August 2012
                : 28
                : 6
                : 1315-1327
                Affiliations
                [1 ]Division of Image Processing, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2300 RC Leiden, The Netherlands
                [2 ]Catheterization Lab, National Center for Cardiovascular Diseases of China and Fu Wai Hospital, A 167, Beilishi Road, Xicheng District Beijing, Beijing, 100037 China
                [3 ]Department of Cardiology, ErasmusMC, Rotterdam, The Netherlands
                Article
                16
                10.1007/s10554-012-0016-6
                3463784
                22261998
                084915ce-bb04-43be-bd2b-f4649eb46951
                © The Author(s) 2012
                History
                : 16 December 2011
                : 4 January 2012
                Categories
                Original Paper
                Custom metadata
                © Springer Science+Business Media Dordrecht 2012

                Cardiovascular Medicine
                optical coherence tomography,intravascular ultrasound,x-ray coronary angiography,qca

                Comments

                Comment on this article

                Related Documents Log