      Orbital, eyelid, and nasopharyngeal silicone oil granuloma presenting as ptosis & pseudo-xanthelasma

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          To highlight the presentation and management of a patient with eyelid, orbital and nasopharyngeal silicone oil migration through a glaucoma drainage implant presenting as pseudo-xanthelasma and ptosis.

          Observations

          A 68-year male presented with unilateral ptosis and presumed xanthelasma. He had a history of glaucoma drainage implant surgery, pseudophakia, and multiple retinal detachment repairs with silicone oil. During ptosis repair it was discovered that his presumed xanthelasma was in fact an eyelid silicone granuloma. Additional work up revealed silicone infiltration of the eyelids, orbits, and nasopharynx, resulting from emulsified silicone oil leakage through his glaucoma valve implant.

          Conclusions and Importance

          Silicone oil may emulsify with time, with potential egress via a glaucoma filtration device. Clinicians should be alert for eyelid, orbital and sinonasal findings that may indicate occult migration.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: not found

          Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery.

          Complicated retinal detachments (RDs) were successfully managed in 150 eyes of 170 consecutive patients by one surgeon (JLF) using silicone oil in conjunction with modern pars plana vitrectomy. Long-term postoperative complications were observed between 6 months and 5 years of follow-up. Cataracts developed in all phakic eyes and all corneas with oil-endothelial touch showed band keratopathy within 6 months. Recurrent detachments were noted in 22% of eyes during silicone oil tamponade and occurred in 13% of eyes after the oil had been removed. Other complications associated with the use of oil for vitreous surgery included pupillary block glaucoma (3%), closure of the inferior iridectomy (14%), fibrous epiretinal and subretinal proliferations (15%), pain (5%), and subconjunctival deposits of oil (3%). Without exception, within a period of 1 year the intraocular silicone oil showed some degree of emulsification, suggesting that the physicochemical characteristics of the oil injected may be an important variable in long-term complications.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Intracranial migration of silicone oil from an eye with optic pit.

            The origin of subretinal fluid in eyes with optic pit remains controversial. Case report. The authors found that silicone oil, implanted into an eye that developed proliferative vitreoretinopathy after surgery for optic pit-related macular detachment, has migrated into the subarachnoid space. As this case shows, cerebrospinal fluid may migrate into the submacular space in eyes with optic pits.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Emulsification of silicone oils with specific physicochemical characteristics.

              To determine the exact role of various factors in silicone-oil emulsification, we investigated eight different silicone oils with specific physicochemical characteristics in terms of their rate of emulsification. The silicone oils were defined by viscosity, volatility, amount of low-molecular components, electrical resistivity, degree of purification and chemical composition. The viscosities differed between the ranges of 1000 and 10,000 cs. The silicone oils included purified polydimethylsiloxane (PDMS), hydroxyl-enriched PDMS and trimethylsiloxy-terminated polydiphenylsiloxane (PDPS). As emulsifiers we used 0.1% solutions of fibrinogen, fibrin, gamma globulins, acidic alpha-1-glycoprotein, very-low-density lipoprotein and serum dissolved in sterile, distilled water as well as in balanced salt solution. The group of low-viscosity silicone oils (1000 cs) was least stable. The greatest difference in stability was found among purified PDMS, having viscosities between 1000 and 5000 cs. The most stable oil was purified PDMS, whose emulsification rate was almost identical at 5000 and 10,000 cs. High contents of hydroxyl end groups enhanced silicone-oil emulsification to a greater extent than did phenyl side groups. The strongest emulsifiers were fibrinogen, fibrin and serum, followed by gamma globulins, very-low-density lipoprotein and acidic alpha-1-glycoprotein. Balanced salt solution accelerated silicone oil emulsification in all cases. For reduction of emulsification in vivo, purified PDMS of high viscosity should be used. Biologically active emulsifiers found in hemorrhages or inflammatory situations might be lowered in vivo by hemostasis and sufficient postoperative anti-inflammatory therapy.
                Bookmark

                Author and article information

                Contributors
                Journal
                Am J Ophthalmol Case Rep
                Am J Ophthalmol Case Rep
                American Journal of Ophthalmology Case Reports
                Elsevier
                2451-9936
                14 May 2018
                September 2018
                14 May 2018
                : 11
                : 45-48
                Affiliations
                [1]Department of Ophthalmology, Byers Eye Institute at Stanford University, 2452 Watson Court, Palo Alto, CA, United States
                Author notes
                []Corresponding author. akossler@ 123456stanford.edu
                Article
                S2451-9936(17)30184-6
                10.1016/j.ajoc.2018.05.003
                6026769
                29978139
                0bc7d31e-b115-490f-bf8e-bc9a00ed8b7e
                © 2018 Published by Elsevier Inc.

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                : 17 June 2017
                : 10 May 2018
                : 11 May 2018
                Categories
                Case report

                silicone oil,xanthelasma,orbit,foreign body granuloma,baerveldt,glaucoma drainage implant

                Comments

                Comment on this article