6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Medical, Technical and Audiological Outcomes of Hearing Rehabilitation with the Bonebridge Transcutaneous Bone-Conduction Implant: A Single-Center Experience

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Bone-conduction implants are a standard therapeutic option for patients with conductive, unilateral, or mixed hearing loss who either do not tolerate conventional hearing aids or can benefit from surgery. The aim of this study was to evaluate long-term medical and technical outcomes, and audiological results with the Bonebridge transcutaneous bone-conduction implant. This retrospective study included all patients implanted with a bone-conduction hearing implant at a tertiary medical referral center between March 2012 and October 2018. Medical and technical outcomes included the mean length of implant usage, medical and technical complications (skin and wound infection, lack of benefit, technical failure), explantations and revisions, coupling approaches, implant failure rate, implant survival and the implant loss for added follow-up years. Auditory results were measured by functional hearing gain and the Freiburger monosyllabic test at 65 dB sound pressure level. Sixty-four patients were included in the study; five of these were implanted bilaterally (69 devices). Five unilaterally implanted patients were lost to follow-up. The mean follow-up was 27.1 months (range: 0.2 months–6.3 years). The mean implant usage was 25.9 months (range: 0.2 months–6.3 years). Fifty-seven implants (89.1%) were in use at the end of the follow-up period. Complications occurred in six ears (9.4%). Five implants (7.8%) were explanted without reimplantation. Device failure occurred in one implant (1.6%), which was possibly caused by recurrent head trauma. The rate of implant loss due to technical device failure (damage to device) was 1 per 72 follow-up years. The mean improvement on the Freiburger monosyllabic test (52.1%, p = 0.0001), and in functional hearing gain across frequencies (26.5 dB, p = 0.0001) was significant. This single-center follow-up reveals the medical and technical reliability of a transcutaneous bone-conduction implant for hearing rehabilitation because complication and revision rates were low. The majority of patients still used the device at the end of the observation period. Implantation resulted in favorable hearing outcomes in comparison to that of unaided conditions. Cautious patient selection mainly regarding co-morbidities, the history of chronic otologic diseases and proper surgical technique seems to be crucial in reducing complications.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          Complications of bone-anchored hearing aid implantation.

          Bone-anchored hearing aid implantations have been performed in Manchester for over 20 years. This study examined a range of variables that can occur during the implantation process, and the effect they may have on successful outcome. Retrospective study and literature review. Tertiary referral centre in central Manchester. Details of 602 bone-anchored hearing aid implantation procedures were retrieved from the departmental database. The overall complication rate was 23.9 per cent. The rate of revision surgery was 12.1 per cent. This study involved a significantly larger number of patients than any previously reported, similar study. Possible reasons for differences in outcomes, and recommendations for best practice, are discussed.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              A New Transcutaneous Bone Conduction Hearing Implant: Short-term Safety and Efficacy in Children

              To investigate the safety and efficacy of a new bone conduction hearing implant in children, during a 3-month follow-up period.
                Bookmark

                Author and article information

                Journal
                J Clin Med
                J Clin Med
                jcm
                Journal of Clinical Medicine
                MDPI
                2077-0383
                03 October 2019
                October 2019
                : 8
                : 10
                Affiliations
                Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria; faris.brkic@ 123456meduniwien.ac.at (F.F.B.); dominik.riss@ 123456meduniwien.ac.at (D.R.); katharina.scheuba@ 123456meduniwien.ac.at (K.S.); wolfgang.gstoettner@ 123456meduniwien.ac.at (W.G.);
                Author notes
                [* ]Correspondence: erich.vyskocil@ 123456meduniwien.com ; Tel.: +43-1-40400-33300
                Article
                jcm-08-01614
                10.3390/jcm8101614
                6832994
                31623414
                0dda7b81-3ef0-4bfe-855e-b0ff4bf3d74e
                © 2019 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                Categories
                Article

                bonebridge,transcutaneous hearing implant,bone conduction,complications,audiological outcomes

                Comments