11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Influence of chlorhexidine digluconate concentration and application time on resin-dentin bond strength durability.

      European Journal of Oral Sciences
      Acetone, chemistry, Acid Etching, Dental, Anti-Infective Agents, Local, administration & dosage, Bisphenol A-Glycidyl Methacrylate, Chlorhexidine, analogs & derivatives, Composite Resins, Dental Bonding, Dental Materials, Dentin, ultrastructure, Dentin-Bonding Agents, Humans, Materials Testing, Microscopy, Electron, Scanning, Organophosphonates, Phosphoric Acids, Polymethacrylic Acids, Silver Staining, Stress, Mechanical, Surface Properties, Temperature, Tensile Strength, Time Factors, Water

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Although it is known that chlorhexidine application may preserve resin-dentin bonds from degradation, the lowest optimal concentration and application time have yet to be established. This study evaluated the effects of different concentrations of chlorhexidine digluconate and different application times on the preservation of resin-dentin bonds formed using two etch-and-rinse adhesives. In experiment 1, after acid etching, the occlusal demineralized dentin was rewetted either with water or with 0.002, 0.02, 0.2, 2, or 4% chlorhexidine for 60 s. In experiment 2, the surfaces were rewetted with water, or with 0.002% or 2% chlorhexidine for 15 or 60 s. After this, both adhesives and composite resin were applied and light-cured. Bonded sticks (0.8 mm(2)) were tested under tension (0.5 mm min(-1)) immediately or after 6 months of storage in water. Two bonded sticks from each tooth were immersed in silver nitrate and analyzed quantitatively using scanning electron microscopy. Reductions in microtensile bond strengths and higher silver nitrate uptake were observed for both adhesives when the rewetting procedure was performed with water. Stable bonds were maintained for up to 6 months under all chlorhexidine conditions tested, irrespective of the chlorhexidine concentration and application time. The use of 0.002% chlorhexidine for 15 s seems to be sufficient to preserve resin-dentin interfaces over a 6-month period.

          Related collections

          Author and article information

          Comments

          Comment on this article