      Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review

      review-article

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective

          Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between accelerometers and the gold standards (indirect calorimetry and doubly labelled water) for the measurement of energy expenditure (EE) in obese or overweight individuals.

          Methods

          The literature search was limited to comparison studies assessing agreement in EE determination between accelerometers and indirect calorimetry (IC) or doubly labelled water (DLW). We searched in PubMed and in Scopus until March 1, 2019. The analysis was restricted to obese or overweight adult individuals. The following descriptive information was extracted for each study: sample size, characteristics of participants (sex, age, BMI, fat mass percentage, any pathological conditions, modality of recruitment in the study, and exclusion criteria), accelerometer description (model, type and body position), and type of gold standard and validity protocol (duration, conditions, and requirements during and before the experiment). Three review authors independently screened the obtained results, and the quality of the selected articles was assessed by the QUADAS-2 tool.

          Results

          We obtained seventeen eligible articles, thirteen of which showed concerns for the applicability section, due to the patient selection. Regarding the accelerometers, nine devices were validated in the included studies with the BodyMedia SenseWear® (SWA) being the most frequently validated. Although correlations between accelerometers and the gold standard were high in some studies, agreement between the two methods was low, as shown by the Bland–Altman plots.

          Conclusions

          Most accelerometer estimations of EE were inaccurate for obese/overweight subjects, and authors advise to improve the accuracy of algorithms for SWA software, or the predicted equations for estimating EE from other accelerometers.

          Related collections

          Most cited references50

          • Record: found
          • Abstract: not found
          • Article: not found

          Practical guide to measuring physical activity.

            • Record: found
            • Abstract: found
            • Article: not found

            Indirect calorimetry: a practical guide for clinicians.

            This review provides clinicians with a comprehensive overview of indirect calorimetry including the principles, methodology, technologic advancements, benefits, and challenges. Clinical applications for indirect calorimetry and the potential limitations are specifically addressed for both the inpatient and outpatient setting. Measurement of energy expenditure is the most accurate method to assess energy needs. Indirect calorimetry remains a gold standard in measuring energy expenditure in the clinical settings. The benefits of providing optimal nutrition for recovery from illness and chronic health management are well documented. Indirect calorimetry offers a scientifically-based approach to customize a patient's energy needs and nutrient delivery to maximize the benefits of nutrition therapy. With recent advances in technology, indirect calorimeters are easier to operate, more portable, and affordable. Increased utilization of indirect calorimetry would facilitate individualized patient care and should lead to improved treatment outcomes.
              • Record: found
              • Abstract: found
              • Article: not found

              Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise.

              To assess the accuracy of the SenseWear Pro Armband for estimating energy expenditure during exercise. : Forty subjects (age = 23.2 +/- 3.8 yr; body mass index = 23.8 +/- 3.1 kg x m) performed four exercises (walking, cycling, stepping, arm ergometry) with each exercise lasting 20-30 min and workload increasing at 10-min intervals. Subjects wore the SenseWear Pro Armband on the right arm, and energy expenditure was estimated using proprietary equations developed by the manufacturer. Estimated energy expenditure from the SenseWear Pro Armband was compared with energy expenditure determined from indirect open-circuit calorimetry, which served as the criterion measure. : When a generalized proprietary algorithm was applied to the data, the SenseWear Pro Armband significantly underestimated total energy expenditure by 14.9 +/- 17.5 kcal (6.9 +/- 8.5%) during walking exercise, 32.4 +/- 18.8 kcal (28.9 +/- 13.5%) during cycle ergometry, 28.2 +/- 20.3 kcal (17.7 +/- 11.8%) during stepping exercise, and overestimated total energy expenditure by 21.7 +/- 8.7 kcal (29.3 +/- 13.8%) during arm ergometer exercise (P < or = 0.001). At the request of the investigators, exercise-specific algorithms were developed by the manufacturer and applied to the data that resulted in nonsignificant differences in total energy expenditure between indirect calorimetry and the SenseWear Pro Armband of 4.6 +/- 18.1 kcal (2.8 +/- 9.4%), 0.3 +/- 11.3 kcal (0.9 +/- 10.7%), 2.5 +/- 18.3 kcal (0.9 +/- 11.9%), and 3.2 +/- 8.1 kcal (3.8 +/- 9.9%) for the walk, cycle ergometer, step, and arm ergometer exercises, respectively. It appears that it is necessary to apply exercise-specific algorithms to the SenseWear Pro Armband to enhance the accuracy of estimating energy expenditure during periods of exercise. When exercise-specific algorithms are used, the SenseWear Pro Armband provides an accurate estimate of energy expenditure when compared to indirect calorimetry during exercise periods examined in this study.

                Author and article information

                Contributors
                Journal
                J Nutr Metab
                J Nutr Metab
                JNME
                Journal of Nutrition and Metabolism
                Hindawi
                2090-0724
                2090-0732
                2020
                4 August 2020
                : 2020
                : 2327017
                Affiliations
                1Department of Biomedical Sciences, University of Cagliari, Cagliari, Italy
                2Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
                3International Agency for Research on Cancer, Nutrition and Metabolism Section, Lyon, France
                Author notes

                Academic Editor: Luigi Schiavo

                Author information
                https://orcid.org/0000-0001-7042-6275
                https://orcid.org/0000-0003-3030-1798
                https://orcid.org/0000-0003-3838-855X
                Article
                10.1155/2020/2327017
                7424495
                32832147
                0fb3106b-1ea4-441f-b656-1374db824d47
                Copyright © 2020 Silvia Pisanu et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 21 October 2019
                : 16 May 2020
                Categories
                Review Article

                Nutrition & Dietetics
                Nutrition & Dietetics

                Comments

                Comment on this article

                Related Documents Log