      Meaningful change and responsiveness in common physical performance measures in older adults.

      Journal of the American Geriatrics Society
      Aged, Aged, 80 and over, Cohort Studies, Exercise Test, Female, Gait, physiology, Humans, Male, Middle Aged, Mobility Limitation, Psychomotor Performance, Recovery of Function, Stroke, physiopathology, rehabilitation, Walking

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To estimate the magnitude of small meaningful and substantial individual change in physical performance measures and evaluate their responsiveness. Secondary data analyses using distribution- and anchor-based methods to determine meaningful change. Secondary analysis of data from an observational study and clinical trials of community-dwelling older people and subacute stroke survivors. Older adults with mobility disabilities in a strength training trial (n=100), subacute stroke survivors in an intervention trial (n=100), and a prospective cohort of community-dwelling older people (n=492). Gait speed, Short Physical Performance Battery (SPPB), 6-minute-walk distance (6MWD), and self-reported mobility. Most small meaningful change estimates ranged from 0.04 to 0.06 m/s for gait speed, 0.27 to 0.55 points for SPPB, and 19 to 22 m for 6MWD. Most substantial change estimates ranged from 0.08 to 0.14 m/s for gait speed, 0.99 to 1.34 points for SPPB, and 47 to 49 m for 6MWD. Based on responsiveness indices, per-group sample sizes for clinical trials ranged from 13 to 42 for substantial change and 71 to 161 for small meaningful change. Best initial estimates of small meaningful change are near 0.05 m/s for gait speed, 0.5 points for SPPB, and 20 m for 6MWD and of substantial change are near 0.10 m/s for gait speed, 1.0 point for SPPB, and 50 m for 6MWD. For clinical use, substantial change in these measures and small change in gait speed and 6MWD, but not SPPB, are detectable. For research use, these measures yield feasible sample sizes for detecting meaningful change.

          Related collections

          Author and article information

          Comments

          Comment on this article