7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Correlation between Corneal Topographic Indices and Higher-Order Aberrations in Keratoconus

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          To compare corneal higher-order aberrations (HOAs) between normal and keratoconic eyes, and to investigate the association between elevation-based corneal topographic indices and corneal wavefront data in the latter group.

          Methods

          In this cross-sectional comparative study, 77 normal right eyes of 77 control subjects and 66 eyes of 36 keratoconic patients were included. In each eye, elevation- based corneal topographic indices including mean keratometry readings, best-fit sphere, maximum elevation, and 3-mm and 5-mm zone irregularity indices were measured using Orbscan II. The Galilei Scheimpflug analyzer was used to measure HOAs of the corneal surface. The independent student t-test was used to compare HOAs between the study groups. Spearman correlation was used to investigate possible associations between Orbscan and Galilei data in the keratoconus group.

          Results

          All Zernike coefficients up to the 4th order except for horizontal trefoil, and vertical and horizontal tetrafoil were significantly greater in the keratoconus group than normal eyes (P<0.05). Root mean square (RMS) of HOAs up to the 6th order and total HOAs were significantly higher in the keratoconus group (P<0.05). In the keratoconus group, the strongest association was observed between vertical coma (r=-0.71, P<0.01) and total RMS of HOAs (r=0.94, P<0.01) with irregularity in the 3-mm zone. Spherical and vertical coma aberrations were significantly correlated with mean keratometry (P<0.05 for both comparisons).

          Conclusion

          Centrally located corneal HOAs are significantly greater in keratoconic eyes than normal controls. Anterior and inferior displacement of the cornea causes the majority of higher-order aberrations observed in keratoconus.

          Related collections

          Author and article information

          Journal
          J Ophthalmic Vis Res
          J Ophthalmic Vis Res
          JOVR
          Journal of Ophthalmic & Vision Research
          Ophthalmic Research Center
          2008-2010
          2008-322X
          April 2013
          : 8
          : 2
          : 113-118
          Affiliations
          Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
          Author notes
          Correspondence to: Sepehr Feizi, MD, MSc. Assistant Professor of Ophthalmology, Labbafinejad Medical Center, Paidarfard St., Boostan 9 St., Pasdaran, Tehran 16666, Iran; Tel: +98 21 2258 5952, Fax: +98 21 2259 0607; e-mail: sepehrfeizi@ 123456yahoo.com
          Article
          JOVR-08-113
          3740462
          23943685
          10fe491c-8c2a-4f1b-b811-227ce0a0b258
          © 2013 Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences

          This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.

          History
          : 20 December 2012
          : 15 February 2013
          Categories
          Original Article

          Ophthalmology & Optometry
          keratoconus,orbscan ii,galilei,higher-order aberrations
          Ophthalmology & Optometry
          keratoconus, orbscan ii, galilei, higher-order aberrations

          Comments

          Comment on this article