7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Biomechanical assessment of stability in the metastatic spine following percutaneous vertebroplasty: effects of cement distribution patterns and volume.

      1 , ,
      Journal of biomechanics
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Percutaneous vertebroplasty is a minimally invasive, radiologically guided procedure whereby bone cement is injected into structurally weakened vertebrae to provide added biomechanical stability. In addition to treating osteoporotic vertebral fractures, this technique is also used to relieve pain by stabilizing metastatically compromised vertebrae that are at risk of pathologic burst fracture. Optimal cement distribution patterns to improve biomechanical stability to metastatically involved vertebral bodies remain unknown. This study aimed to determine the effect of cement location and volume of cement injected during percutaneous vertebroplasty on improving vertebral stability in a metastatically-compromised spinal motion segment using a parametric poroelastic finite element model. A three-dimensional parametric finite element model of a thoracic spinal motion segment was developed and analyzed using commercially available software. A total of 16 metastatic pre and post vertebroplasty scenarios were investigated using a serrated spherical representation of tumor tissue and various geometric representations of polymethylmethacrylate (PMMA). The effect of vertebroplasty on vertebral bulge, a measure of posterior vertebral body wall motion as an indicator of burst fracture initiation, was assessed. In all cases, vertebroplasty reduced vertebral bulge, but the risk of the initiation of burst fracture was minimized with cement located posterior to the tumor, near the posterior vertebral body wall. Vertebral bulge decreased by up to 62% with 20% cement injection. These findings demonstrate that location and distribution of cement within the vertebral body has a noticeable effect on the restoration of biomechanical stability following percutaneous vertebroplasty.

          Related collections

          Author and article information

          Journal
          J Biomech
          Journal of biomechanics
          Elsevier BV
          0021-9290
          0021-9290
          Aug 2005
          : 38
          : 8
          Affiliations
          [1 ] Department of Surgery, Orthopaedic Biomechanics Laboratory, Sunnybrook and Women's College Health Sciences Centre, 2075 Bayview Avenue, UB19 Toronto, Ont., Canada M4N 3M5.
          Article
          S0021-9290(04)00376-8
          10.1016/j.jbiomech.2004.07.023
          15958214
          115fb8c9-0a78-493b-94fa-863b665c116e
          History

          Comments

          Comment on this article