      The influence of His bundle pacing on tricuspid valve functioning using three-dimensional echocardiography

      brief-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction Key Teaching Points • In most patients, the His bundle pacing (HBP) lead is positioned on the atrial side of the His bundle; in others, it is positioned in the tricuspid valve or on the ventricular side of the His bundle. • Echocardiography showed no worsening of tricuspid regurgitation severity in any patient with a permanent HBP, even in those whose leads were located on or under the tricuspid valve. • The HBP lead tip can be positioned in a commissural position in the right ventricle without impinging on leaflet mobility. The His bundle (HB) is located in the right atrium and right ventricle under the membranous ventricular septum. Recently, His bundle pacing (HBP) has re-emerged as an alternative to ventricular pacing strategy; it has been shown to successfully narrow the surface QRS complex and improve left ventricular dyssynchrony. However, ventricular lead–induced tricuspid regurgitation (TR) can occur as a complication of HBP and is associated with a poor prognosis. In most patients, the HBP lead is positioned on the atrial side of the HB; in others, it is positioned in the tricuspid valve (TV) or on the ventricular side of the HB. An association was established between the HBP lead position and lead-induced TR using three-dimensional (3D) echocardiography in our research. In a previous study, long-term follow-up echocardiography during the 1 to 1.5 years after device implantation showed that 38% of the patients developed right ventricular lead–induced TR, defined as an increase to grade 2 or 3 TR. 1 However, TR induced by the HBP remains poorly understood. Therefore, in the present study, we determined the association between the HBP lead position and lead-induced TR using 3D echocardiography. Case report We successfully implanted permanent HBP (dual-chamber pacemakers) in 45 patients according to the guidelines. In most of these patients, the tip positions of the HBP leads were located. However, we were able to visualize the device lead crossing the TV using 3D echocardiography in 6 patients. In 5 of these patients, we observed that the tips were positioned under the TV, where the branching portion of the HB is suggested. In 1 patient, the tip of the lead was located on the TV, where the penetrating portion of the HB is suggested. The penetrating portion of the HB is located near the tricuspid septal leaflet, whereas the branching portion of the HB is located on the posterior sites of the muscular interventricular septum just inferior to the tricuspid septal leaflet. In all 5 patients in whom the tip of the HBP lead was located under the TV, the 3D echocardiogram revealed that the tip of the HBP lead was located in the ventricle via the commissure of the anterior and septal leaflets without impinging leaflet mobility (Figure 1 and Supplemental Video 1). Figure 1 Three-dimensional echocardiographic image of the His bundle pacing lead, seen from the right ventricular apex. The tip of the lead (white arrow) was positioned under the tricuspid valve through the anteroseptal commissure. AV = aortic valve; CS = coronary sinus; HBP = His bundle pacing; MV = mitral valve; RA = right atrium; RV = right ventricle; TV = tricuspid valve. During long-term follow-up (mean duration of 12.5 months), 3D echocardiography showed no deterioration in TR in any patient, even the 6 patients whose leads were positioned on or under the TV. Three patients had trace-to-mild (grade 0–1) and 2 patients had moderate-to-severe (grade 2–3) TR. Moderate-to-severe TR in these 2 patients improved to mild after pacemaker implantation. Before and after pacemaker implantation, pulmonary artery pressure was calculated for each patient from the peak TR jet velocity; this showed no significant change (before, 32 ± 2.5 mm Hg; after, 30 ± 2.4 mm Hg; P = .53). No rise in pacing threshold or lead dislodgment was seen during long-term follow-up. Discussion Previous studies have demonstrated that positioning of the HBP in the commissural position is associated with a less severe TR. 2 In the present study, we assessed the relationship between the HBP lead position and TV functioning using 3D echocardiography. We found that the tip of the HBP lead could be positioned in a commissural position in the right ventricle without impinging on leaflet mobility. These results confirmed that the HBP lead position does not affect TV function, even if the lead is implanted on the ventricular side of the HB. It is thought that HBP can be applied without negatively affecting long-term prognosis, when compared with the use of right ventricular apical or septal pacing.

          Related collections

          Most cited references2

          • Record: found
          • Abstract: found
          • Article: not found

          Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up.

          Although the presence of an RV lead is a potential cause of tricuspid regurgitation (TR), the clinical impact of significant lead-induced TR is unknown.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation.

            This study sought to: 1) determine the feasibility of using 3-dimensional transthoracic echocardiography (3D TTE) in patients with implantable cardiac resynchronization devices, pacemakers, and defibrillators to visualize the device leads in the right heart and their position relative to the tricuspid valve leaflets; 2) determine the prevalence of different lead positions; and 3) study the relationship between lead location and tricuspid regurgitation (TR) severity.
              Bookmark

              Author and article information

              Contributors
              Journal
              HeartRhythm Case Rep
              HeartRhythm Case Rep
              HeartRhythm Case Reports
              Elsevier
              2214-0271
              18 June 2018
              September 2018
              18 June 2018
              : 4
              : 9
              : 437-438
              Affiliations
              []Department of Cardiovascular Medicine, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
              []Department of Ubiquitous Health Informatics, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
              []Department of Advanced Cardiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
              Author notes
              [] Address reprint requests and correspondence: Dr Eriko Hasumi or Dr Katsuhito Fujiu, Department of Cardiovascular Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, Japan 113-8655. ehasumi-circ@ 123456umin.ac.jp fujiu-tky@ 123456umin.ac.jp
              Article
              S2214-0271(18)30103-9
              10.1016/j.hrcr.2018.06.003
              6140415
              30228973
              12efdf43-f950-4c40-add0-38fd34c734c2
              © 2018 Heart Rhythm Society. Published by Elsevier Inc.

              This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

              History
              Categories
              Image

              his bundle,his bundle pacing,lead-induced tricuspid regurgitation,three-dimensional echocardiography,tricuspid valve commissure

              Comments

              Comment on this article