44
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Quantifying cellular oxidative stress by dichlorofluorescein assay using microplate reader.

      1 ,
      Free radical biology & medicine
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Oxidative stress (OS) has been implicated in various degenerative diseases in aging. In an attempt to quantify OS in a cell model, we examined OS induced by incubating for 30 min with various free radical generators in PC12 cells by using the dichlorofluorescein (DCF) assay, modified for use by a fluorescent microplate reader. The nonfluorescent fluorescin derivatives (dichlorofluorescin, DCFH), after being oxidized by various oxidants, will become DCF and emit fluorescence. By quantifying the fluorescence, we were able to quantify the OS. Our results indicated that the fluorescence varied linearly with increasing concentrations (between 0.1 and 1 mM) of H2O2 and 2,2'-azobios(2-amidinopropane) dihydrochloride (AAPH; a peroxyl radical generator). By contrast, the fluorescence varied as a nonlinear response to increasing concentrations of 3-morpholinosydnonimine hydrochloride (SIN-1; a peroxynitrite generator), sodium nitroprusside (SNP; a nitric oxide generator), and dopamine. Dopamine had a biphasic effect; it decreased the DCF fluorescence, thus acting as an antioxidant, at concentrations <500 microM in cells, but acted as a pro-oxidant by increasing the fluorescence at 1 mM. While SNP was not a strong pro-oxidant, SIN-1 was the most potent pro-oxidant among those tested, inducing a 70 times increase of fluorescence at a concentration of 100 microM compared with control. Collectively, due to its indiscriminate nature to various free radicals, DCF can be very useful in quantifying overall OS in cells, especially when used in conjunction with a fluorescent microplate reader. This method is reliable and efficient for evaluating the potency of pro-oxidants and can be used to evaluate the efficacy of antioxidants against OS in cells.

          Related collections

          Author and article information

          Journal
          Free Radic Biol Med
          Free radical biology & medicine
          Elsevier BV
          0891-5849
          0891-5849
          Sep 1999
          : 27
          : 5-6
          Affiliations
          [1 ] Neuroscience Laboratory, USDA-ARS, Jean Mayer USDA Human Nutrition Research Center on Aging at Tufts University, Boston, MA 02111, USA. wang_us@hnrc.tufts.edu
          Article
          S0891-5849(99)00107-0
          10.1016/s0891-5849(99)00107-0
          10490282
          157cb2ba-2763-40d5-95e8-1a46bba1a994
          History

          Comments

          Comment on this article