      The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients.

      Intensive Care Medicine
      Aged, Blood Pressure, physiology, Blood Pressure Determination, methods, Critical Care, statistics & numerical data, Critical Illness, Feasibility Studies, Female, Femoral Artery, Humans, Intensive Care Units, Male, Middle Aged, United States

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The T-Line TL-200 (Tensys Medical, San Diego, CA, USA) is a non-invasive arterial blood pressure (BP) monitoring system allowing continuous "beat-to-beat" monitoring of systolic arterial pressure (SAP), mean arterial pressure (MAP), and diastolic arterial pressure (DAP). It provides a real-time BP waveform like that obtained using an arterial catheter. The aim of this study was to compare BP measurements obtained using the T-Line TL-200 with simultaneous invasive BP measurements using a femoral arterial catheter in unselected critically ill medical patients. In 28 patients treated in a medical intensive care unit (ICU), BP values were simultaneously obtained using a femoral arterial catheter and the T-Line TL-200. All recorded data were included in the final analysis. For comparison of BP measurements, Bland-Altman analysis accounting for repeated measurements was performed (primary endpoint). A total of 76,826 pairs of BP measurements (each consisting of SAP, MAP, and DAP) were analyzed. For MAP, Bland-Altman analysis revealed a mean difference of +0.47 mmHg (95 % limits of agreement -16.53 to +17.46 mmHg). For SAP and DAP, the bias and 95 % limits of agreement were -9.01 mmHg (-37.47 to +19.45 mmHg) and +5.22 mmHg (-13.50 to +23.94 mmHg), respectively. Non-invasive, continuous, radial BP measurement with the T-Line TL-200 is basically feasible in medical ICU patients (with a low bias for MAP compared to MAP assessed using a femoral arterial catheter). High limits of agreement (particularly of SAP and DAP) preclude the use of the device as a single source of BP information in unstable critically ill patients.

          Related collections

          Author and article information

          Comments

          Comment on this article