0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry

      , ,
      American Journal of Ophthalmology
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Scanning laser polarimetry uses an anterior segment compensating device that assumes a fixed axis of corneal birefringence, which we call the corneal polarization axis. The purpose of this investigation was to establish the distribution of corneal polarization axes among a population of normal eyes and to evaluate the relationship between corneal polarization axis and posterior segment retardation. We constructed a noninvasive slit lamp-mounted device incorporating two crossed linear polarizers and an optical retarder in order to measure the slow axis of corneal birefringence. Normal subjects underwent corneal polarization axis measurement. A subset of eyes underwent scanning laser polarimetry of the peripapillary retinal nerve fiber layer (n = 32) and macula (n = 29), and retardation measurements were evaluated in each group. One hundred eighteen eyes of 63 normal subjects (35 female, 28 male) underwent corneal polarization axis measurement (mean age, 45.5 +/- 17.1 years). Six eyes (5.1%) demonstrated unmeasurable corneal polarization. In the remaining 112 eyes, the mode of the corneal polarization axis distribution was 10 to 20 degrees nasally downward (range, 90 degrees nasally downward to 54 degrees nasally upward). A significant (P <.0001) correlation was observed between fellow eyes (R(2) =.52), with a mean difference of 11.2 +/- 10.5 degrees (range, 0-52 degrees). Corneal polarization axis was significantly associated (R(2) =.52-.84) with retinal nerve fiber layer and macula summary retardation parameters (average thickness, ellipse average, superior and inferior average, superior and total integral; P <.0001 for all groups). The mean corneal polarization axis among normal corneas is nasally downward; however, considerable intraindividual and interindividual variability exists. The linear relationship between corneal polarization axis and posterior segment retardation parameters is responsible, in part, for the wide distribution of retinal nerve fiber layer thickness data generated by scanning laser polarimetry.

          Related collections

          Author and article information

          Journal
          American Journal of Ophthalmology
          American Journal of Ophthalmology
          Elsevier BV
          00029394
          June 2000
          June 2000
          : 129
          : 6
          : 715-722
          Article
          10.1016/S0002-9394(00)00353-6
          10926978
          15b617cc-00fa-4d6f-b13f-cd24598549a9
          © 2000

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article