13
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Evaluation of Turbidimetric Inhibition Immunoassay (TINIA) and HPLC Methods for Glycated Haemoglobin Determination

      research-article

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Various factors may affect the accuracy of hemoglobin (Hb) A1c measurements that are widely used to monitor glycemic control in diabetic patients. This study was aimed to compare the values of HbA1c obtained by two different methods, Roche Tina‐quant second and thirdgeneration HbA1c assays based on the turbidimetric inhibition immunoassay (TINIA), and high‐performance liquid chromatography (HPLC) cation‐exchange method used by Arkray Adams HA‐8160 analyzer.

          Methods

          Measurements of HbA1c were carried out in blood samples from 2,917 patients using above‐mentioned methods. Linear regression was used for the correlation analysis and linear equations. Bland–Altman plots were performed from method comparison data using MedCalc statistical software.

          Results

          For the low control, the second generation Tina‐quant assay had within‐run and between‐run CVs 0.8% and 0.9%; for the high control within‐run and between‐run CVs were 1% and 0.96%, respectively. HPLC method for the low control had within‐run CV 1% and between‐run CV 1.3%; for the high control within‐run CV was 0.6% and between‐run CV was 0.9%.

          Conclusion

          There was a good concordance between the results of TINIA and HPLC methods ( y = 1.091 x – 0.363; r 2 = 0.96).

          Related collections

          Author and article information

          Journal
          J Clin Lab Anal
          J. Clin. Lab. Anal
          10.1002/(ISSN)1098-2825
          JCLA
          Journal of Clinical Laboratory Analysis
          John Wiley and Sons Inc. (Hoboken )
          0887-8013
          1098-2825
          09 November 2012
          November 2012
          : 26
          : 6 ( doiID: 10.1002/jcla.2012.26.issue-6 )
          : 481-485
          Affiliations
          [ 1 ] Istanbul Faculty of Medicine Department of Biochemistry Istanbul University Istanbul Turkey
          [ 2 ] Istanbul Faculty of Medicine Department of Public Health Istanbul University Istanbul Turkey
          Author notes
          [*] [* ]Correspondence to: Professor Figen Gurdol, Department of Biochemistry, Istanbul Faculty of Medicine, Istanbul University, Çapa, 34093, Istanbul, Turkey. E‐mail: figur@ 123456istanbul.edu.tr
          Article
          PMC6807436 PMC6807436 6807436 JCLA21550
          10.1002/jcla.21550
          6807436
          23143632
          178695d1-8d61-47f5-901f-59e51b65363a
          © 2012 Wiley Periodicals, Inc.
          History
          : 16 January 2012
          : 02 August 2012
          Page count
          Pages: 5
          Categories
          Research Article
          Research Articles
          Custom metadata
          2.0
          JCLA21550
          November 2012
          Converter:WILEY_ML3GV2_TO_NLMPMC version:5.7.0 mode:remove_FC converted:23.10.2019

          turbidimetric immunoassay (TINIA),diabetes mellitus,high‐performance liquid chromatography (HPLC),HbA1c

          Comments

          Comment on this article

          Related Documents Log