2
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      CORRELACIÓN DE VALORES β-HCG Y ULTRASONOGRAFÍA INTRAOPERATORIA EN EMBARAZO ECTÓPICO Translated title: CORRELATION OF β-HCG LEVELS AND INTRA-OPERATIVE ULTRASONOGRAPHY IN ECTOPIC PREGNANCY

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introducción: El diagnóstico del embarazo ectópico puede no resultar fácil y se debe realizar con rapidez y seguridad, pues una demora puede conllevar a la ruptura, la hemorragia y poner en peligro la vida de la paciente. Objetivo: Determinar el grado de correlación de valores de β-hCG y ultrasonografía con los hallazgos intra-operatorios de pacientes con diagnóstico de embarazo ectópico en el servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés. Material y métodos: Estudio descriptivo transversal y retrospectivo. Se estudiaron 115 pacientes con diagnóstico de embarazo ectópico, internadas en el Servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés, durante el periodo 2010 - 2014. Resultados: La población con mayor frecuencia afectada, es de 20 a 30 años de edad (88,7%). La mayor cantidad de población, se observó durante el año 2014 (47%). La validez de los hallazgos ultrasonográficos es de: Sensibilidad = 98,2% y Especificidad = 75%. La seguridad de los hallazgos ultrasonográficos es de: Valor Predictivo Positivo = 99,1% y Valor Predictivo Negativo = 60%. La validez de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de: Sensibilidad = 99,1% y Especificidad = 100%. La seguridad de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de: Valor Predictivo Positivo = 100% y Valor Predictivo Negativo = 80%. Conclusión: El test diagnóstico ultrasonográfico combinado con la cuantificación sérica de β-hCG tiene mayor validez y seguridad que el test diagnóstico ultrasonográfico solo.

          Translated abstract

          Introduction: The diagnosis for ectopic pregnancy may be difficult, and must be carried out quickly and safely since a delay can lead to rupture, bleeding and endanger the life of the patient. Objective: To determine the correlation degree of β-hCG levels and ultrasonography with the intra-operative findings of patients with ectopic pregnancy diagnosis in the Gynecology and Obstetrics Service at Hospital Municipal Boliviano Holandés. Material and methods: Descriptive, cross-sectional and retrospective study that included 115 patients with ectopic pregnancy diagnosis, and admitted in the Obstetrics and Gynecology Service at Hospital Municipal Boliviano Holandés during the period 2010-2014. Results: The most frequently affected population was 20 to 30 years old (88.7%). Most of the cases were observed during 2014 (47%). Validity of ultrasound findings reflected 98.2% of sensitivity and 75 % of specificity. Safety of ultrasound findings reflected Positive Predictive Value of 99.1 % and Negative Predictive Value of 60 %. Validity of ultrasound findings combined with β-hCG serum quantification displayed a sensitivity of 99.1 % and specificity of100%. Safety of ultrasound findings combined with β-hCG serum quantification displayed a Positive Predictive Value of 100 % and Negative Predictive Value of 80 %. Conclusions: The ultrasonographic diagnostic test combined with the β-hCG serum quantification has better validity and safety than the ultrasonographic test alone.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: not found
          • Book: not found

          Metodología de la investigación

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Metrotexate y conducta expectante

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              ¿Se diagnostica siempre a tiempo un embarazo ectópico?

                Bookmark

                Author and article information

                Journal
                rmcmlp
                Revista Médica La Paz
                Rev. Méd. La Paz
                Colegio Médico de La Paz (La Paz, , Bolivia )
                1726-8958
                2020
                : 26
                : 1
                : 18-23
                Affiliations
                [02] orgnameHospital del Norte orgdiv1Ortopedia y Traumatología
                [01] El Alto La Paz orgnameHospital Municipal Boliviano Holandés orgdiv1Ginecología y Obstetricia Bolivia crispindey@ 123456gmail.com
                Article
                S1726-89582020000100003 S1726-8958(20)02600100003
                17a80f51-a5b7-406c-aa4a-10e0eb4f3543

                This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

                History
                : 28 October 2019
                : 08 April 2020
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 15, Pages: 6
                Product

                SciELO Bolivia

                Self URI: Texto completo solamente en formato PDF (ES)
                Categories
                ARTÍCULO ORIGINAL

                -hCG,ectopic pregnancy,ultrasonography,seguridad,validez,ultrasonografía,embarazo ectópico

                Comments

                Comment on this article