          Abstract

          Weak gravitational lensing studies aim to measure small distortions in the shapes of distant galaxies, and thus place very tight demands on the understanding of detector-induced systematic effects in astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will carry out weak lensing measurements in the near infrared using the new Teledyne H4RG-10 detector arrays, which makes the range of possible detector systematics very different from traditional weak lensing measurements using optical CCDs. One of the non-linear detector effects observed in CCDs is the brighter-fatter effect (BFE), in which charge already accumulated in a pixel alters the electric field geometry and causes new charge to be deflected away from brighter pixels. Here we describe the formalism for measuring the BFE using flat field correlation functions in infrared detector arrays. The auto-correlation of CCD flat fields is often used to measure the BFE, but because the infrared detector arrays are read out with the charge "in place," the flat field correlations are dominated by capacitive cross-talk between neighboring pixels (the inter-pixel capacitance, or IPC). We show that because the infrared detector arrays can be read out non-destructively, one can compute numerous cross-correlation functions between different time slices of the same flat exposures, and that correlations due to IPC and BFE leave distinct imprints. We generate a suite of simulated flat fields and show that the underlying IPC and BFE parameters can be extracted, even when both are present in the simulation. There are some biases in the BFE coefficients up to 12%, which are likely caused by higher order terms that are dropped from this analysis. The method is applied to laboratory data in the companion Paper II.

          Related collections

          Author and article information

          Journal
          05 June 2019
          Article
          1906.01846
          17e5337b-9c23-40e8-a604-82138bd1a818

          http://arxiv.org/licenses/nonexclusive-distrib/1.0/

          History
          Custom metadata
          44 pages, 4 figures, 1 table, comments welcome
          astro-ph.IM astro-ph.CO

          Cosmology & Extragalactic astrophysics,Instrumentation & Methods for astrophysics

          Comments

          Comment on this article