7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Echocardiographic measurements alone do not provide accurate non-invasive selection of annuloplasty band size for robotic mitral valve repair.

      The Journal of heart valve disease
      Adult, Aged, Cardiac Surgical Procedures, methods, Echocardiography, Transesophageal, Female, Humans, Intraoperative Period, Male, Middle Aged, Mitral Valve, pathology, surgery, ultrasonography, Mitral Valve Insufficiency, complications, etiology, Mitral Valve Prolapse, Motion, Nomograms, Postoperative Period, Reoperation, Retrospective Studies, Robotics, Systole, Ventricular Function, Left, physiology

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Successful mitral valve repair (MVP) is dependent on accurate annuloplasty band sizing. This is difficult and time-consuming when performed via port-access, or through a 4-cm minithoracotomy used in robotically assisted MVP. With the goal of moving toward a less-invasive approach and minimizing cross-clamp time, an attempt was made to determine annuloplasty band size using transesophageal echocardiography (TEE) alone. The intertrigonal distance (ITD) was determined by dividing the left ventricular outflow tract diameter (LVOT: measured on standard midesophageal aortic valve long-axis view) by 0.8. The ITD was compared to a nomogram developed to select the best Cosgrove-Edwards annuloplasty band size. Between July and October, 2004, 11 patients (mean age 52.6 +/- 17.9 years; four Barlow's valves with bileaflet prolapse, four posterior leaflet prolapses, one anterior leaflet prolapse, one rheumatic, one dilated annulus) undergoing robotically assisted MVP had the annuloplasty band chosen using TEE alone. Seven patients (63.6%) had no or mild mitral regurgitation (MR) on postoperative TEE. Three patients (27.2%) had some systolic anterior motion (SAM), with one (Barlow's valve) requiring a second repair (same operation). One patient (9.1%, rheumatic) had grade 2+ MR on postoperative TEE. In this small case series, a substantial proportion of patients had suboptimal immediate postoperative results. This suggests that selection of the annuloplasty band should not be based on a single echocardiographic variable as it depends on the etiology of the MR, and other dimensions of the mitral valve. Further studies are ongoing to develop a non-invasive method for the selection of annuloplasty band size.

          Related collections

          Author and article information

          Comments

          Comment on this article