Validation of recorded data is a prerequisite for studies that utilize administrative databases. The present study evaluated the validity of diagnoses and procedure records in the Japanese Diagnosis Procedure Combination (DPC) data, along with laboratory test results in the newly-introduced Standardized Structured Medical Record Information Exchange (SS-MIX) data.
Between November 2015 and February 2016, we conducted chart reviews of 315 patients hospitalized between April 2014 and March 2015 in four middle-sized acute-care hospitals in Shizuoka, Kochi, Fukuoka, and Saga Prefectures and used them as reference standards. The sensitivity and specificity of DPC data in identifying 16 diseases and 10 common procedures were identified. The accuracy of SS-MIX data for 13 laboratory test results was also examined.
The specificity of diagnoses in the DPC data exceeded 96%, while the sensitivity was below 50% for seven diseases and variable across diseases. When limited to primary diagnoses, the sensitivity and specificity were 78.9% and 93.2%, respectively. The sensitivity of procedure records exceeded 90% for six procedures, and the specificity exceeded 90% for nine procedures. Agreement between the SS-MIX data and the chart reviews was above 95% for all 13 items.
Validity of DPC and SS-MIX data was tested using chart review results as references.
Specificity of DPC diagnoses was high; sensitivity was low and varied by conditions.
Procedure records in DPC data were highly sensitive and specific.