3
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Novel Polymeric Valve for Transcatheter Aortic Valve Replacement Applications: In Vitro Hemodynamic Study

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <p class="first" id="P1">Transcatheter aortic valve replacement (TAVR) is a minimally-invasive approach for treating severe aortic stenosis. All clinically-used TAVR valves to date utilize chemically-fixed xenograft as the leaflet material. Inherent limitation of the tissue (e.g., calcific degeneration) motivates the search for alternative leaflet material. Here we introduce a novel polymeric TAVR valve that was designed to address the limitations of tissue-valves. In this study, we experimentally evaluated the hemodynamic performance of the valve and compared its performance to clinically-used valves: a gold standard surgical tissue valve, and a TAVR valve. Our comparative testing protocols included: (i) baseline hydrodynamics (ISO:5840–3), (ii) complementary patient-specific hydrodynamics in a dedicated system, and (iii) thrombogenicity. The patient-specific testing system facilitated comparing TAVR valves performance under more realistic conditions. Baseline hydrodynamics results at CO 4–7 L/min showed superior effective orifice area (EOA) for the polymer valve, most-notably as compared to the reference TAVR valve. Regurgitation fraction was higher in the polymeric valve, but within the ISO minimum requirements. Thrombogenicity trends followed the EOA results with the polymeric valve being the least thrombogenic, and clinical TAVR being the most. Hemodynamic-wise, the results strongly indicate that our polymeric TAVR valve can outperform tissue valves. </p>

          Related collections

          Most cited references32

          • Record: found
          • Abstract: found
          • Article: not found

          Aortic Bioprosthetic Valve Durability

          In recent times, there has been a considerable increase in the use of aortic bioprostheses (vs. mechanical prostheses) for treating aortic valve disease, and this tendency is likely to continue in the near future. However, the occurrence of structural valve degeneration, limiting valve durability, remains an important drawback of surgical and transcatheter bioprostheses. In this paper, we provide an overview of bioprosthetic valve durability, focusing on the definition, incidence, mechanisms, predictive factors, and management of structural degeneration of aortic bioprostheses.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            The Fluid Mechanics of Transcatheter Heart Valve Leaflet Thrombosis in the Neosinus

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Durability of prostheses for transcatheter aortic valve implantation.

              Transcatheter aortic valve implantation (TAVI) has become the standard of care for inoperable patients, and the preferred treatment option for high-risk patients with severe aortic stenosis. Given that this therapy was intended for elderly patients with limited life expectancy, long-term durability has not been in the focus. Now that TAVI is increasingly being used in patients with intermediate-risk and lower-risk profiles, device durability has gained importance. The available mid-term results for TAVI are promising; however, little is known about the fate of TAVI devices beyond 5 years. The experience with long-term durability of surgical valves shows that ≥10-year follow-up is required to ensure reliable durability data. In this Review, we discuss the existing studies of TAVI durability, highlight differences between surgical and transcatheter treatment of aortic stenosis that might influence durability, and present a clinical solution for failed prostheses. Furthermore, we suggest how device durability might influence the future selection of patients for TAVI.
                Bookmark

                Author and article information

                Journal
                Annals of Biomedical Engineering
                Ann Biomed Eng
                Springer Science and Business Media LLC
                0090-6964
                1573-9686
                January 2019
                September 7 2018
                January 2019
                : 47
                : 1
                : 113-125
                Article
                10.1007/s10439-018-02119-7
                6475193
                30194551
                1c92c204-eea2-49c8-a86c-5a11b7b2de31
                © 2019

                http://www.springer.com/tdm

                History

                Comments

                Comment on this article