      Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

      Hypertension
      Adult, Blood Pressure, Catheters, Indwelling, Female, Fingers, blood supply, Heart Rate, Humans, Male, Middle Aged, Monitoring, Physiologic, Nitroglycerin, pharmacology, Plethysmography, methods, Pressoreceptors, physiology, Rest

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The accuracy of blood pressure values obtained by continuous noninvasive finger blood pressure recording via the FINAPRES device was evaluated by comparison with simultaneous intraarterial monitoring both at rest and during performance of tests known to induce fast and often marked changes in blood pressure. The comparison was performed in 24 normotensive or essential hypertensive subjects. The average discrepancy between finger and intra-arterial blood pressure recorded over a 30-minute rest period was 6.5 +/- 2.6 mm Hg and 5.4 +/- 2.9 mm Hg for systolic and diastolic blood pressure, respectively; a close between-method correspondence was also demonstrated by linear regression analysis. The beat-to-beat changes in finger systolic and diastolic blood pressure were on average similar to those measured intra-arterially during tests that induced a pressor or depressor response (hand-grip, cold pressor test, diving test, Valsalva maneuver, intravenous injections of phenylephrine and trinitroglycerine) as well as during tests that caused vasomotor changes without major variations in blood pressure (application of lower body negative pressure, passive leg raising). The average between-method discrepancy in the evaluation of blood pressure changes was never greater than 4.3 and 2.0 mm Hg for systolic and diastolic blood pressure, respectively; the corresponding standard deviations ranged between 4.6 and 1.6 mm Hg. Beat-to-beat computer analysis of blood pressure variability over the 30-minute rest period provided standard deviations almost identical when calculated by separate consideration of intra-arterial and finger blood pressure tracings (3.7 and 3.8 mm Hg, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          Relationship of 24-hour blood pressure mean and variability to severity of target-organ damage in hypertension.

          Casual blood pressure (BP) can predict the development of cardiovascular morbidity and mortality, but the correlations between its values and the subsequent occurrence of such complications are low. This may depend on different individual resistance to the damage produced by hypertension. However, it may also depend on the recognized inability of causal BP to reflect accurately the 24-h mean and profile BP. In order to test the latter hypothesis, 24-h BP was recorded intra-arterially (Oxford method) in 108 hospitalized subjects with essential hypertension ranging from mild to severe. The 24-h means and standard deviations (i.e. variabilities) for systolic, mean and diastolic BP obtained by computer analysis of the BP tracing were related to the rate and severity of target-organ damage (TOD) assessed by clinical examination and quantified according to a predetermined score. The results confirmed that 24-h BP may be variably different from cuff BP among subjects. For nearly any value of cuff BP, subjects in whom the 24-h mean BP was low had a lower prevalence and severity of TOD than those in whom the 24-h mean BP was high (P less than 0.01). Furthermore, for nearly any level of 24-h mean BP, subjects in whom the 24-h BP variability was low had a lower prevalence and severity of TOD than those in whom the 24-h BP variability was high (P less than 0.05). These findings demonstrate that the severity of hypertension is more closely related to 24-h mean BP than to cuff BP values.(ABSTRACT TRUNCATED AT 250 WORDS)
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Evaluation of the baroreceptor-heart rate reflex by 24-hour intra-arterial blood pressure monitoring in humans.

            The baroreceptor control of the sinus node was evaluated in 10 normotensive and 10 age-matched essential hypertensive subjects in whom ambulatory blood pressure was recorded intra-arterially for 24 hours and scanned by a computer to identify the sequences of three or more consecutive beats in which systolic blood pressure (SBP) and pulse interval (PI) progressively rose (+PI/+SBP) or fell (-PI/-SBP) in a linear fashion, according to a method validated in cats. In normotensive subjects, several hundred +PI/+SBP and -PI/-SBP sequences of 3 beats were found whereas the number of sequences of 4, 5, and more than 5 beats showed a progressive drastic reduction. The mean slopes of +PI/+SBP (7.6 +/- 2.0 msec/mm Hg) and -PI/-SBP (6.4 +/- 1.5 msec/mm Hg) sequences were similar, but in both instances there was a large scattering of the values around the mean (variation coefficients: 64.2 +/- 4.7 and 62.6 +/- 2.4%). The slopes decreased as a function of the sequence length and baseline heart rate and increased to a marked extent during the night as compared with daytime values. All sequences were more rare (-33.2% for +PI/+SBP and -31.7% for -PI/-SBP) and less steep in hypertensive subjects (-40.3 and -36.2%, respectively), who failed to show the marked nighttime increase in slope observed in normotensive subjects. To our knowledge, these observations provide the first description in humans of the baroreceptor-heart rate reflex in daily life. This reflex is characterized by marked within-subject variations in sensitivity due in part to hemodynamic, temporal, and behavioral factors.(ABSTRACT TRUNCATED AT 250 WORDS)
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Blood pressure and heart rate variabilities in normotensive and hypertensive human beings.