      Correlation between Retinal Nerve Fiber Layer Thickness by Optical Coherence Tomography and Perimetric Parameters in Optic Atrophy

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          To investigate the correlation between retinal nerve fiber layer (RNFL) thickness determined by optical coherence tomography (OCT) and visual field (VF) parameters in patients with optic atrophy.

          Methods

          This study was performed on 35 eyes of 28 patients with optic atrophy. RNFL thickness was measured by OCT (Carl Zeiss, Jena, Germany) and automated perimetry was performed using the Humphrey Field Analyzer (Carl Zeiss, Jena, Germany). The correlation between RNFL thickness and VF parameters was evaluated.

          Results

          Mean global RNFL thickness was 44.9±27.5 μm which was significantly correlated with mean deviation score on automated perimetry (r=0.493, P=0.003); however, no significant correlation was observed between visual field pattern standard deviation and the corresponding quadrantic RNFL thickness. In a similar manner, no significant association was found between visual acuity and RNLF thickness.

          Conclusion

          Mean global RNFL thickness as determined by OCT seems to be correlated with VF defect depth as represented by the mean deviation score on Humphrey VF testing. OCT may be used as an objective diagnostic tool in the evaluation of patients with optic atrophy.

          Related collections

          Most cited references12

          • Record: found
          • Abstract: found
          • Article: not found

          Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy.

          The number and distribution of human optic nerve axons were compared with clinical measurements available the same eyes, including visual acuity, disc appearance, and visual field studies. Definite loss of axons occurs prior to reproducible visual field defects in some patients suspected of having glaucoma. In glaucoma, the superior and inferior poles of the nerve lose nerve fibers at a selectively greater rate, leading to an hourglass-shaped atrophy. Cavernous degeneration of the retrobulbar optic nerve is rarely observed in chronic glaucoma. The pattern of atrophy in examples of toxic amblyopia, ischemic optic neuropathy and chronic papilledema differ from that of glaucoma, suggesting different mechanisms of damage in these conditions.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography.

            Optical coherence tomography (OCT) is a new technology that uses near-infrared light in an interferometer to produce approximately 10-microns resolution cross-sectional images of the tissue of interest. The authors performed repeated quantitative assessment of nerve fiber layer thickness in individuals with normal and glaucomatous eyes, and they evaluated the reproducibility of these measurements. The authors studied 21 eyes of 21 subjects by OCT. Each subject underwent five repetitions of a series of scans on five separate occasions within a 1-month period. Each series consisted of three circular scans around the optic nerve head (diameters, 2.9, 3.4, and 4.5 mm). Each series was performed separately using internal (fixation with same eye being studied) and external (fixation with contralateral eye) fixation techniques. The eye studied and the sequence of testing were assigned randomly. Internal fixation (IF), in general, provides a slightly higher degree of reproducibility than external fixation (EF). Reproducibility was better in a given eye on a given visit than from visit to visit. Reproducibility as measured by intraclass correlation coefficients were as follows: circle diameter (CD), 2.9 mm, 0.51/0.57 (normal/glaucoma) (IF), 0.43/0.54 (EF); CD, 3.4 mm, 0.56/0.52 (IF), 0.43/0.61 (EF); CD, 4.5 mm, 0.53/0.43 (IF), 0.42/0.49 (EF). Nerve fiber layer thickness can be reproducibly measured using OCT. Internal is superior to external fixation; each circle diameter tested provides adequate reproducibility.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

              The measurement reproducibility of the third generation of commercial optical coherence tomography, OCT-3 (StratusOCT, software ver. A2, Carl Zeiss Meditec Inc., Dublin, CA) was investigated. The nerve fiber layer (NFL) thickness, macula thickness map, and optic nerve head (ONH) parameters in normal eyes were studied. Ten normal subjects were imaged six times (three before and three after dilation) per day, and the series was repeated on three different days. The order of the scans before pupil dilation was randomized in each of the 3 days of scanning. After pupil dilation, the scans were also randomized in each of the 3 days of scanning. Each series was performed separately for standard-density (128 A-scans per macular and ONH image and 256 A-scans per NFL image) and high-density (512 A-scans per image for all three scan types) scanning. The mean macular thickness was 235 +/- 9.8 micro m. A-scan density (or image acquisition speed) had a statistically significant effect (P < 0.05) on the reproducibility of the mean macular thickness, macular volume, and a few sectors of the macular map. No significant dilation effect was found for any of the macular parameters. The best intraclass correlation coefficient (ICC; 94%) for macular scans was found for dilated high-density scanning, with an intervisit SD of 2.4 micro m and an intravisit SD of 2.2 micro m. The mean NFL thickness for standard scanning was 98 +/- 9 micro m. NFL reproducibility showed mixed results and had interactions between scan density and dilation for some parameters. For most of the NFL parameters, reproducibility was better with dilated standard-density scanning. The mean NFL thickness ICC for dilated standard scanning was 79%, with an intervisit SD of 2.5 micro m and an intravisit SD of 1.6 micro m. For the ONH analysis, the reproducibility was better for dilated standard-density scanning for almost all the parameters, except for disc area, horizontal integrated rim volume, and vertical integrated rim area, which were better before dilation. The best reproducibility was found for cup-to-disc ratio (ICC = 97%, with intervisit SD of 0.04 micro m and intravisit SD of 0.02 micro m). StratusOCT demonstrated reproducible measurements of NFL thickness, macular thickness, and optic nerve head parameters. The best reproducibility was found for dilated standard scanning for NFL and ONH parameters and for dilated high-density scanning for macular parameters.
                Bookmark

                Author and article information

                Journal
                J Ophthalmic Vis Res
                J Ophthalmic Vis Res
                JOVR
                Journal of Ophthalmic & Vision Research
                Ophthalmic Research Center
                2008-2010
                2008-322X
                April 2008
                : 3
                : 2
                : 91-94
                Affiliations
                Ophthalmic Research Center, Rasoul Akram Hospital, Iran Medical University, Tehran, Iran
                Author notes
                Correspondence to: Khalil Ghasemi-Falavarjani, MD. Assistant Professor of Ophthalmology; Eye Research Center, Rasoul Akram Hospital, Niayesh St., Sattarkhan Ave., Tehran 14455-364, Iran; Tel: +98 21 66509162 , Fax: +98 21 66509162 ; e-mail: drghasemi@ 123456yahoo.com
                Article
                jovr-3-91
                3589224
                23479529
                201da937-0b1e-404c-b8e5-558ecdfcba97
                © 2008 Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences

                This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.

                History
                : 17 December 2007
                : 5 March 2008
                Categories
                Original Article

                Ophthalmology & Optometry
                Ophthalmology & Optometry

                Comments

                Comment on this article